INSTALLATION INSTRUCTIONS FOR THE
MICRO SWITCH GLS MIN-DIN SERIES
GLOBAL LIMIT SWITCH
Instrucciones de instalación para los MICRO SWITCH interruptores limite global (serie GLS MIN-DIN)
Einbauanweisungen für den MICRO SWITCH Global Endschalter (Serie GLS MIN-DIN)
Instructions d'installation du MICRO SWITCH fin de course mondiales (série GLS MIN-DIN)
Istruzioni per l'installazione del MICRO SWITCH finecorsa globali (Serie GLS MIN-DIN)
Instruções de Instalação para o MICRO SWITCH de limite global (Série GLS MIN-DIN)
MICRO SWITCH 全球限位开关( GLS MIN-DIN 系列)安装指南
m WARNING
IMPROPER INSTALLATION
•
Consult with local safety agencies and their
requirements when designing a machine-control link,
interface, and all control elements that affect safety.
•
Strictly adhere to all installation instructions.
Failure to comply with these instructions could result in
death or serious injury.
MOUNT, WIRE, AND SEAL THE SWITCH
m WARNING
IMPROPER OPERATION
•
Ensure switch actuator achieves sufficient travel for
positive opening of normally closed (NC) contacts to
occur.
Failure to comply with these instructions could result in
death or serious injury.
Ui 300V ac/dc metal
Ui 300 Vdc/600 Vac plastic
UL EN 50047
EN60947-5-1
CCC GB 14048.5
EN45545-2 HL 3 (GLC & GLE Series switches only)
EN61373 (GLC & GLE Series switches only)
1.
Refer to:
•
Page 5 for adjustments
•
Pages 8 to 12 for specific travel distances for each
switch code and specifications
•
Page 5 for proper application of limit switches
•
Page 13 to 18 for switch mounting dimensions
2.
Perform adjustments (if desired):
•
Head orientation (Figure 1, page 5)
•
Actuation direction (Figure 2, page 5)
•
Side rotary switches with 36 drive lever positions
(Figure 3, page 5):
3.
Mount switch at top corners of switch using two M4 or #8
screws. For GLD products torque screws to 2,7 Nm to 3,4
Nm [24 in-lb to 30 in-lb]. For GLC & GLE products torque
screws to 3,1 Nm to 3,7 Nm [27 in-lb to 33 in-lb].
4.
Remove screws on cover plate.
5.
Connect stranded wire (0,75 mm
or solid wire (0,75 mm
block terminals (use 90 °C wire when ambient temperature
is over 75 °C). Torque switch terminal screws to 0,8 Nm to
1,0 Nm [7 in-lb to 9 in-lb].
6.
Seal conduit opening according to instructions in PK
80112.
7.
Reassemble cover plate, and torque cover screws to 0,5 Nm
[4.4 in-lb].
81521
Issue 11
2
to 2,3 mm
2
, 18-14 AWG)
to 1,5 mm
, 18-16 AWG) to contact
2
2