Technical data
For dimensions, refer to "Dimensions" from page 73 on.
Tightening torques for the fixing nuts
Emergency stop
Actuator with 16 mm thread
Actuator with 22 mm thread
Hygienic areas
SNH 0300
Operating elements
The following information applies for these items:
SNH 0100, SNH 0200, SNH 0300, SNH 0400, SNH 0500, SNH 0600, SNH 0700
Case material
Material resistance against
Acids, bases, alcohols
−
hydrocarbons (petroleum, oil, etc.)
−
UV-irradiation, ozone
−
Protection class
Operating ambient temperature
without illumination
−
with LED illumination
−
Storage temperature
Switching cycles
Max. torque
Installation diameter
LED illumination
Power supply rated voltage
−
Voltage range
−
Current consumption
−
Doc. # BA000612 – 01/2019 (Rev. C)
Tightening torques
min.
1.5 Nm
Plastic
good
none/limited
high
IP65 (IEC 60529)
SNH 0100, 0200, 0300, 0600: IP69k
-30 ... +70 °C
-30 ... +55 °C
-50 ... +85 °C
> 50.000 : SNH 0300 : 6050
2,5 Nm
22,3 mm
24 V AC/DC
12 ... 30 V AC/DC
24 V / 15 mA
max.
1.5 Nm
2.5 Nm
2.2 Nm
EN 18 / 74