Switching elements
The following information applies for these items:
SNH 0001, SNH 0002, SNH 0003, SNH 0011, SNH 0012, SNH 0013, SNH 0021, SNH 0022, SNH
0023, SNH 0031, SNH 0032, SNH 0033, SNH 0043, SNH 0044
Protection class
Ambient operating temperature
without illumination
−
Storage temperature
Switching elements switching principle
Utilisation category
Rated;insulation voltage U
Connection technology (contacts)
Minimum switching voltage
Minimum switching current
Max. wire cross section
Thermal continuous current
Max. contact resistance
Max. bounce time
Min. positive break travel
Rated current I
/ rated voltage U
e
B
value
10d
Mechanical service life
Electrical service life
(for rated load)
Contact material
Operating travel
Doc. # BA000612 – 01/2019 (Rev. C)
SNH 00xx
II
-30 ... +85 °C
-50 ... +85 °C
Slow-action switching element
AC15 A600: 250 V AC 3 A
DC13 Q600: 24 V DC 2 A
(EN 60947-5-1)
600 V
i
Screw clamp connection
5 V
1 mA
2.5 mm²
16 A
20 mΩ
20 ms
3 mm
16 (10) A for 250 V AC
e
10 (6) A for 440 V AC
(EN 61058-1)
250,000 switching cycles
1 × 10
1 × 10
AgNi
6 mm
switching cycles
6
switching cycles
6
SNH 0043
AC15 A300
250 V AC 3 A
300 V
16 (10) A for 250 V
AC
(EN 61058-1)
>104,000 switching
cycles
1 × 10
switching
5
cycles
1 × 10
switching
5
cycles
EN 19 / 74