TECHNICAL DATA
Relay output:
Ambient temperature:
Response time:
Electrical connection:
Enclosure:
Enclosure dimensions:
Cable gland:
Protective tube:
Process connection:
Protection class:
Protection type:
Standards:
Optional:
®
AERASGARD
ACO
- W
2
®
AERASGARD
ALQ - CO
®
AERASGARD
AFTM - CO
®
AERASGARD
AFTM - LQ - CO
Type ⁄ WG02
ACO
-W
2
A C O 2 -W
A C O 2 -W- D I S P L AY
ALQ - CO
-W
2
A L Q - C O 2 -W
A L Q - C O 2 -W- D I S P L AY
AFTM - CO
2
A F T M - C O 2 -W
A F T M - C O 2 -W- D I S P L AY
AFTM - LQ - CO
2
A F T M - L Q - C O 2 -W
A F T M - L Q - C O 2 -W D I S P L AY
Outputs:
Note:
Accessories
SF-M
WS-03
- W ⁄ ALQ - CO
- W ⁄ AFTM - CO
2
2
with potential-free changeover contact (24 V), 1 A ohmic load
(assignment selectable via DIP switches)
–10...+60 °C
< 2 minutes
0.14 - 1.5 mm
2
, via screw terminals
plastic, polyamide, 30 % glass-globe reinforced,
with quick-locking screws (slotted ⁄ Phillips head combination),
colour traffic white (similar to RAL 9016), enclosure cover for display is transparent!
126 x 90 x 50 mm (Tyr 2)
M 16 x 1.5; including strain relief, exchangeable
stainless steel, Ø 16 mm, NL = 55 mm
by screws
III (according to EN 60 730)
IP 65 (according to EN 60 529)
CE conformity, electromagnetic compatibility according to EN 61 326,
EMC Directive 2014 ⁄ 30 ⁄ EU
three-line display with illumination, cutout approx. 70 x 40 mm (W x H),
for displaying actual humidity, actual temperature, air quality and / or the actual CO
On-wall sensor for CO
- W
On-wall sensor for CO
2
Multifunctional on-wall sensor
2
for humidity, temperature and CO
Multifunctional on-wall sensor
2
for humidity, temperature, CO
Measuring Range
Humidity
Temperature
0...100 % r.H.
–35...+80 °C
0...100 % r.H.
–35...+80 °C
0...100 % r.H.
–35...+80 °C
0...100 % r.H.
–35...+80 °C
0 - 10 V or 4...20 mA (selectable via DIP switches, selected variant applies for all outputs)
This unit must not be used as safety-relevant device!
Metal sinter filter, Ø 16 mm, L = 32 mm, exchangeable
stainless steel (VA 1.4404)
Weather and sun protection, 200 x 180 x 150 mm, stainless steel
⁄ AFTM - LQ - CO
2
content, Deluxe
2
content and air quality (VOC), Deluxe
2
content, Deluxe
2
content and air quality (VOC), Deluxe
2
CO
VOC
2
(switchable)
0...2000 ⁄ 5000 ppm
0...2000 ⁄ 5000 ppm
(switchable)
0...2000 ⁄ 5000 ppm
0...100 %
0...2000 ⁄ 5000 ppm
0...100 %
(switchable)
0...2000 ⁄ 5000 ppm
0...2000 ⁄ 5000 ppm
(switchable)
0...2000 ⁄ 5000 ppm
0...100 %
0...2000 ⁄ 5000 ppm
0...100 %
11
Rev. 2017 - V20 GB
2
content
2
Display
Item No.
1501-7110-7301-200
1501-7110-7371-200
1501-7111-7301-200
1501-7111-7371-200
1501-7116-7301-200
1501-7116-7371-200
1501-7118-7301-200
1501-7118-7371-200
7000-005 0-2200-100
7100-0040-6000-000