6000-2970-0000-1XX 20700-2018 V102 02 ⁄ 2018
THERMASGARD
® 
THERMASGARD
® 
D
Bedienungs- und Montageanleitung
Anlegetemperaturfühler ⁄ Rohranlegefühler,
incl. Spannband, mit passivem Ausgang
G
Operating Instructions, Mounting & Installation
Surface contact temperature sensors ⁄ tube contact
temperature sensors, including strap, with passive output
F
Notice d'instruction
Sonde de température à applique ⁄ sonde d'applique pour
conduites, y compris collier de serrage, avec sortie passive
r
Руководство по монтажу и обслуживанию
Датчик температуры накладной ⁄ накладной для труб,
вкл. хомут, с пассивным выходом
S+S REGELTECHNIK GMBH
PIRNAER STRASSE 20
90411 NÜRNBERG ⁄ GERMANY
FON +49 (0) 911 ⁄ 5 19 47- 0
FAX +49 (0) 911 ⁄ 5 19 47- 70
mail@SplusS.de
www.SplusS.de
ALTF 2
ALTF 02
Herzlichen Glückwunsch!
Sie haben ein deutsches Qualitätsprodukt erworben.
Congratulations!
You have bought a German quality product.
Félicitations !
Vous avez fait l'acquisition d'un produit allemand de qualité.
Примите наши поздравления !
Вы приобрели качественный продукт, изготовленный в Германии.
ALTF 2
(IP 65)
ALTF 02
(IP 43)

Publicité

Table des Matières
loading

Sommaire des Matières pour S+S Regeltechnik THERMASGARD ALTF 2

  • Page 1 Руководство по монтажу и обслуживанию Датчик температуры накладной ⁄ накладной для труб, вкл. хомут, с пассивным выходом ALTF 02 (IP 43) S+S REGELTECHNIK GMBH Herzlichen Glückwunsch! Sie haben ein deutsches Qualitätsprodukt erworben. PIRNAER STRASSE 20 Congratulations! 90411 NÜRNBERG ⁄ GERMANY You have bought a German quality product.
  • Page 2 D G F r ALTF 2 THERMASGARD ®  ALTF 02 THERMASGARD ®  ALTF 2 Maßzeichnung ALTF 02 Dimensional drawing Plan coté Габаритный чертеж M16x1.5 M16x1.5 ALTF 02 ALTF 2 (IP 43) (IP 65) High-Performance-Verguss gegen Vibration, mechanischer Belastung und Feuchtigkeit High-performance encapsulation against vibration, mechanical stress and humidity P S - P R O T E C T I O N P ERF EC T S E N S O R P R O T EC T I O N...
  • Page 3: Technische Daten

    ® THERMASGARD ALTF 2 ⁄ ALTF 02 Rev. 2018 - V14 DE Der THERMASGARD ® ALTF 2 ist ein Rohranlegewiderstandsthermometer mit passivem Ausgang, mit Spann­ 1x Zweileiterschaltung band und Klemmkastengehäuse aus schlagzähem Kunststoff und Gehäusedeckel mit Schnellverschluss schrauben. Standard Der THERMASGARD ®...
  • Page 4 Allgemeine Informationen Messprinzip für HLK - (HVAC) -Temperaturfühler allgemein: Das Messprinzip der Temperaturfühler beruht darauf, dass der innen liegende Sensor ein temperaturabhängiges Widerstandssignal abgibt. Die Art des innen liegenden Sensors bestimmt das Ausgangssignal. Man unterscheidet die nachfolgenden passiven ⁄ aktiven Temperatursensoren: a) Pt 100 - Messwiderstand (nach DIN EN 60 751) b) Pt 1000 - Messwiderstand (nach DIN EN 60751) c) Ni 1000 - Messwiderstand (nach DIN EN 43 760, TCR=6180 ppm ⁄...
  • Page 5: Achtung, Hinweis

    Montage und Installation Die Geräte sind im spannungslosen Zustand anzuschließen. Der Hinweise zum mechanischen Ein- und Anbau: Anschluss der Geräte darf nur an Sicherheitskleinspannung er- Der Einbau hat unter Berücksichtigung der einschlägigen, für den folgen. Folgeschäden, welche durch Fehler an diesem Gerät ent- Messort gültigen Vorschriften und Standards (wie z.
  • Page 6: Technical Data

    ® THERMASGARD ALTF 2 ⁄ ALTF 02 Rev. 2018 - V14 GB THERMASGARD ® ALTF 2 is a tube contact resistance thermometer with passive output, strap and terminal 1x two­wire connection box enclosure made of impact­resistant plastic and enclosure cover with quick­locking screws. Standard THERMASGARD ®...
  • Page 7 General notes Measuring principle of HVAC temperature sensors in general: The measuring principle of temperature sensors is based on an internal sensor that outputs a temperature-dependent resistance signal. The type of the internal sensor determines the output signal. The following active ⁄ passive temperature sensors are distinguished: a) Pt 100 measuring resistor (according to DIN EN 60 751) b) Pt 1000 measuring resistor (according to DIN EN 60751) c) Ni 1000 measuring resistor (according to DIN EN 43 760, TCR = 6180 ppm ⁄...
  • Page 8 Mounting and Installation Devices are to be connected under dead-voltage condition. Devices Notes regarding mechanical mounting and attachment: must only be connected to safety extra-low voltage. Consequential Mounting shall take place while observing all relevant regulations damages caused by a fault in this device are excluded from war- and standards applicable for the place of measurement (e.g.
  • Page 9: Caractéristiques Techniques

    ® THERMASGARD ALTF 2 ⁄ ALTF 02 Rev. 2018 - V14 FR La sonde THERMASGARD ® ALTF 2 est un thermomètre d’applique à résistance pour conduites avec sortie 1 x 2 fils passive, collier de serrage et boîte à bornes en matière plastique résiliente et couvercle de boîtier avec vis Standard de fermeture rapide.
  • Page 10: Généralités

    Généralités Principe de mesure des sondes de température pour applications CVC (HVAC) en général: Le principe de mesure se base sur le fait que le capteur à l’intérieur génère un signal de résistance dépendant de la température. Le signal de sortie est déterminé par le type de capteur qui se trouve à l’intérieur. On distingue les capteurs de température actifs et passifs suivants: a) Pt 100 –...
  • Page 11: Montage Et Installation

    Montage et installation Les raccordements électriques doivent être exécutés HORS Consignes pour l’installation mécanique : TENSION. Veillez à ne brancher l’appareil que sur un réseau de Effectuer le montage en tenant compte des dispositions et règles très basse tension de sécurité. Nous déclinons toute responsabi- standards à...
  • Page 12: Технические Данные

    ® THERMASGARD ALTF 2 ⁄ ALTF 02 Rev. 2018 - V14 RU Датчик THERMASGARD ® ALTF 2 является накладным термометром сопротивления для труб с пассивным 1x Двухпроводное подключение выходом, стяжной лентой и клеммным коробчатым корпусом из пластика с высокой ударной вязкостью, и крышкой стандартное...
  • Page 13 Указания к продуктам Общий принцип измерения для датчика температуры HLK (HVAC): Принцип измерения температуры основан на зависимости электрического сопротивления чувствительного элемента (сенсора), находя- щегося внутри датчика, от температуры. Выходной сигнал сопротивления определяется типом чувствительного элемента. Различают следующие пассивные ⁄ активные чувствительные элементы: а) измерительный...
  • Page 14: Монтаж И Подключение

    Монтаж и подключение Приборы следует устанавливать в обесточенном состоянии. Под- Указания к механическому монтажу: ключение должно осуществляться исключительно к безопасно ма- Монтаж должен осуществляться с учетом соответствующих, дей- лому напряжению. Повреждения приборов вследствие несоблюде- ствительных для места измерения предписаний и стандартов ния...
  • Page 15 Reprints, in part or in total, are only permitted with the approval of S+S Regeltechnik GmbH. La reproduction des textes même partielle est uniquement autorisée après accord de la société S+S Regeltechnik GmbH. Перепечатка, в том числе в сокращенном виде, разрешается лишь с согласия S+S Regeltechnik GmbH.
  • Page 16 D G F r Widerstandskennlinien für passive Temperatursensoren Resistance characteristics of passive temperature sensors Courbes caractéristiques pour capteurs de température passive Характеристики сопротивления пассивных датчиков температуры PT 100 PT 1000 Ni 1000 Ni 1000 LM235Z TK 5000 (T1) 81-210 (KP10) °...