ACCTIVA EASY 1206
Art. Nr.:
4,010,XXX,XXX
Chr. Nr.:
00000000000000
In:
110-230V / 50-60Hz 48W
Out:
12V = 2,5 - 4Aarith
Always stop charging before you disconnect the charging cable!
Toujours arrêter la charge avant de débrancher le câble de charge!
A
B
00007432420000
SELECTIVA 1006
Art. Nr.:
Chr. Nr.:
4,010,XXX,XXX
00000000000000
In:
110-230V / 50-60Hz 48W
Out:
12V = 2,5 - 4Aarith
Always stop charging before you disconnect the charging cable!
Toujours arrêter la charge avant de débrancher le câble de charge!
00007432420000
NOTE!
Danger due to selector switch being set incorrectly.
Setting the selector switch incorrectly can result in the following:
Charger displays incorrect test results.
Charger switches to "error"
Battery will not be fully charged.
Vehicle power supply will be damaged (e.g. in back-up mode).
► Always set the selector switch to the correct position.
NOTE!
Danger from charging dry batteries (primary cells).
This can result in damage to property.
► It is not permitted to use this charger to charge dry batteries (primary cells).
Acctiva Easy 1202, 1204, 1206, 2403
Charging characteristic setting:
Setting A: For charging all lead acid starter batteries
Setting B: Always use setting B to charge stationary batteries in
standby applications (e.g.: emergency power systems) or in
ambient temperatures exceeding 35 °C!
Selectiva 1006, 2003
Charging characteristic setting:
Setting A: For charging all lead acid traction batteries
Setting B: Always use setting B to charge stationary batteries in
standby applications (e.g.: emergency power systems) or in
ambient temperatures exceeding 35 °C!
27