112 |
WARNING:
If the following models:
E6P2M - E7P2M - E7PQ2M - E7P2M/VTR - E9PQ2M -
E9P2MP/VTR - SE9P2MP/VTR - SE9P2MP/VTR-BF are
installed as a single unit (not in a row), fix the anti-tilt
bracket to the floor by using the proper anchor screws
(see Fig. 1a); consider the minimum installation distances
described above. The free-standing appliances that weigh
less than 40 kg, must be fixed to the surface where they
rest by using the supplied fixing kit (see Fig. 1b).
Unscrew one of the legs and insert the pin in the largest
hole of the bracket "A", screw in the leg again with a
"B" screw. Always consider the minimum distance of
installation.
Before performing any operation, cut off the main
power supply.
For a direct network connection, it is necessary to
provide a device that ensures the disconnection from
EN
the network with an opening distance from the
contacts that allows for a complete disconnection
under the conditions of overvoltage category III, in
accordance to the rules of installation.
For the LX models, the power supply cable can be
connected/replaced after installing the unit.
On the back of the unit, there is a compartment
that the technician can easily reach to perform the
connection.
Attention!
Never interrupt the yellow-green ground cable.
ELECTRICAL CONNECTION
Connect the unit to the mains, following the provided
instructions (see Fig. 4 – Fig. 5):
1) Install, if not present, a disconnecting switch (A) close
to the appliance with a thermal magnetic release and
differential locking.
2) Open the doors (B), if present, and loosen the screws (C)
to disassemble the control panel (D).
3) Connect the disconnecting switch (A) to the terminal
board (H) as shown in the figure and in the electrical
diagrams at the end of this manual. The chosen
connection cable must have features similar to the
H07RN-F type cable with an operating temperature of
at least 80°C and have a section suitable to the unit (see
the Technical Data table).
4) Pass the cable through the passage and tighten
the cable stopper, connect the conductors in their
corresponding position to the terminal board and
attach them. The yellow-green ground conductor must
be longer than the others so that, in the event that
the cable stopper breaks, it disconnects itself after the
voltage cables.
5) If the power supply cord is damaged, replace it with
a special cable of H05RNF or H07RNF type: to prevent
any risk, have the cord replaced by the manufacturer or
their Technical Assistance or by a qualified person.
EQUIPOTENTIAL
The appliance must be connected to an equipotential
system. The connection terminal is close to the entrance
of the power supply cord.
It is marked by the following symbol:
Attention!
The manufacturer is not responsible and will not
reimburse, under the guarantee, damages due to the
improper installation and installation that does not
MOD.
N°:
Qn
conform to these instructions.
V
kW:
Hz: 50/60
IP
APPLIANCE TEST
Important
Before putting the unit in operation, test the
equipment to evaluate the operational conditions
of each component and single out any possible
anomalies.
During this phase, it is important that the safety and
hygiene conditions are strictly followed.
Carry out the following controls to perform the test:
1) Check that the main voltage is in conformity with the
appliance voltage
2) Use the automatic disconnecting switch to check the
electrical connection
3) Check the proper operation of safety devices
After testing, if necessary, train the users so that they
understand all the necessary skills to operate the equipment
in safe conditions, according to the regulations in force in
the country in which the equipment is to be used.
USE INSTRUCTIONS
This type of apparatus is to be used for commercial
applications, for example restaurant kitchens,
canteens, hospitals and commercial businesses, such
as bakeries, butchers, etc., but not for continual mass
production of food.
ATTENTION!
Use the appliances under supervision and never
operate while empty.
Pilot lights indicate if every unit is on or off.
The appliance does not need particular adjustment
interventions by specialized people except for the
regulations made during the user's operation.