Télécharger Imprimer la page

Agilent Technologies TwisTorr 74 FS AG Mode D'emploi page 183

Masquer les pouces Voir aussi pour TwisTorr 74 FS AG:

Publicité

N.
Read/ Write
147
R/W
155
R
157
R/W
161
R/W
162
R/W
163
R/W
167
R/W
200
R
201
R
202
R
203
R
TwisTorr 74 FS AG On-board Controller User Manual / 87-901-054-01
Data
Description
Type
N
Vent open time
See "vent connector" paragraph
N
Power limit applied
Read the maximum permitted power
N
Gas load type
Select the gas load to the pump
N
Pressure Reading Connection Factor
See "GAUGE CONNECTOR" for more details
A
R1 Set Point Pressure Valve
Valid if Win. 101 = 4
Format X.X E. XX
Where X = 0 to 9 s = + or -
N
Pressure unit of measure
A
Stop speed reading
Activates / deactivates the pump speed
reading after Stop command
N
Pumpcurrent in mA dc
N
Pump voltage in Vdc
N
Pump power in W (pump current x pump
voltage)
N
Driving frequency in Hz
Technical Information
Description
Permitted Values
0 = infinite
1 bit = 0.2 sec
1 to 65535
watt
Ø = N
2
1 = Ar
0 to 10
0 = 0
10 = 1 = N
2
0 = mBar
1 = Pa
2 = Torr
0 = disable
1 = enable
(default = 0)