Trouble shooting
Electric motor does not operate
- Check that the battery main switch is 'ON'.
- Check whether the control panel fuse has burnt out.
- Check if the main fuse has burnt out.
In all the above cases the 'POWER' indicator lamp will not be
on. Check if it is possible to turn the propeller. A piece of wood
or similar could have been caught between the propeller and
the tunnel.
Electric motor turns slowly
- The battery is flat.
- Bad electrical connection(s) due to e.g. corrosion.
- The carbon brushes are not making proper contact.
- The battery capacity is reduced because of very low tem-
peratures.
- Weed or fishing line has become caught in the propeller.
Control panel fuse is burnt out
- Short circuit in the operating circuit; check the wiring.
Electric motor turns (too) fast but there is no thrust
- The propeller blades are damaged because of an object in
the tunnel.
The bow thruster loses oil
- Remove the tailpiece from the thrust tunnel and have the lip
seals replaced.
1
) The control current fuse is in the bow thruster motor.
2
) Bow thruster
Fuse: 'slow blow'
BOW6012B (12 V)
BOW6024B (24 V)
Operation manual and installation instructions Bow thruster 60 kgf, ø 185 mm
1
)
2
)
1
)
Art. code
200 A
ZE200
100 A
ZE100
      ENGLISH
19
020547.02

Publicité