Télécharger Imprimer la page

Assembly/Installation - Jotul I 500 FL Manuel D'installation Et Données Techniques

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 18
ENGLISH
Weight must not be transferred from the fireplace structure to the
chimney. The fireplace structure must not hinder the chimney's
ability to move, and must not be anchored to the chimney.
For recommended chimney draught, see "2.0 Technical Data". If
the draught is too strong, a flue pipe damper can be installed
and used to reduce the draught.
3.6 Preparation/installation
NB: Check that the fireplace is undamaged before installation
begins.
The product is heavy! Ensure you have help when positioning
and installing it.
Attaching the legs and securing the base
heat shield (Fig. 3)
1. Unpack the insert. Take out the box with contents and, if
necessary, burn plates to make the product lighter. Close the door.
2. To make the installation easier, the entire front, including the
door, air chamber and exhaust deflector, can be removed. See
section "4.0 Service".
3. Lay the insert carefully down on its back (you can protect the
floor with the wooden pallet and cardboard packaging).
4. Assemble the 3 legs (A) with the 3 adjustable joints (C) using
the 3 screws and nuts that are in a bag in the box. Then attach
these to the insert using the three (3) M6 x 25 mm countersunk
screws (B) and washers. The screws and washers are already
attached to the base of the insert. Turn the adjustable joints
to obtain the required height.
5. Assemble the heat shield (Fig. 3H) under the base of the insert
using one (1) M6 nut and a washer.
6. Stand the burn chamber up.
7. Make final adjustments to the legs once the insert has been
test-mounted. The bracket (D) should be placed under the
screw heads to protect the surface and to prevent the insert
from slipping out of place. Make final adjustments using the
M10 x 45 mm screws attached to the joints.
8. Refit all the parts that were removed for easier handling of
the insert.
Log retainer (Fig. 5)
Mount the log retainer onto the knobs on the rear of the front
frame.
Assembling the smoke outlet (Fig. 6)
1. Position the smoke outlet (A), which is packed in the box, on
the top of the insert so that the screw attached to it is facing
forwards.
2. Place a clamping iron (B) on each side and attach with a
M8 x 30 mm screw (C) and nut.

3.7 Assembly/installation

Installation to the chimney (Fig. 7)
1. Test-mount the insert first without making a hole in the
chimney. See Fig. 1 for distances to firewall.
2. The flue pipe bend should be assembled directly onto the
insert and should be able to rotate 360
is assembled on the inside of the smoke outlet or the Ø 175
mm is assembled on the outside.
3. Place the insert into its final position. Secure the flue pipe in
the insert's smoke outlet using gasket rope.
NB: It is important that the joints are completely sealed. Air
leakage may cause malfunction.
16
3.8 Checking the functions (Fig. 8)
Check the control handles once the insert is in place. These should
move easily and work in a satisfactory manner.
Air vent (A)
Left position = closed
Right position = open
0
. Flue pipe Ø 150 mm

Publicité

Chapitres

loading