4.3.3. Explanation of display symbols and LEDs
Description of display messages:
Display message
No message
---
A01
A02
A03
A05
A06
There are 2 LEDs on the control card
Designation
LED 1 (item 3)
LED 2 (item 4)
5. Periodic maintenance and cleaning
The machine must only be operated in a fault-free condition! You must shut down the machine immediately
if you discover any damage or malfunction!
Caution!
Risk of physical injury to people and animals and material damage!
• only perform maintenance and cleaning work when the machine is switched off. Disconnect the mains plug!!
• maintenance and cleaning work must only be carried out by trained personnel
• illegible or damaged stickers (e.g. type plate) must be replaced immediately with new ones.
5.1. Overview of maintenance schedule:
Component
Visual inspection of mechanical +
electrical safety technology
Gears
Screw connections
Moving parts (plastic guides, rollers,
rubber buffers, bearings underneath)
Brushes
Entire machine
Description
No mains power connected
Machine ready for operation
Overvoltage alarm - over 260 V
Maximum running time exceeded alarm -
control has not switched off for 20 minutes (sensor faulty / mis-adjusted)
Brushes blocked 5 x in sequence alarm
Control card overheating alarm (> 60 °C)
Control card low temperature alarm (< -30 °C)
Colour
Red
Red
Cleaning
Description
Flashing: Machine ready for operation – > no problem
Permanently illuminated: Control card out of order
Permanently illuminated:
3 A fuse 6 (item 5) faulty
Not illuminated: 3 A fuse 6 (item 5) functioning
Lubrication
x
x
x
38
Inspection
Frequency
x
Daily
x
x
Weekly
x
x
Quarterly