6.2 Setting the start address and
the number of DMX channels
For separate control of all DMX units connected
to the light controller, each unit must have its
own start address . Example: If the first DMX
channel of the MINICUBE-60 is to be controlled
by the light controller via DMX address 6, set
the start address on the MINICUBE-60 to 6 . All
other DMX channels of the MINICUBE-60 will
be automatically assigned to the subsequent
addresses .
Examples with different start addresses:
Number
Start
of DMX
address
channels
MINICUBE-60
1
8
6
1
23
24
1
27
486
1
69
444
1) Press the button MENU once: The display will
show
DMX Address
2) Press the button ENTER . The address starts
flashing . Use the button UP or DOWN to set
the start address within 8 seconds .
3) Press the button ENTER: The display will show
again .
DMX Address
4) Press the button MENU once: The display will
show
Channel Mode
5) Press the button ENTER . The number of DMX
channels starts flashing . Use the button UP or
DOWN to set the number within 8 seconds .
6) Press the button ENTER to save the setting .
All rights reserved by MONACOR
reproduced in any form or by any means for any commercial use.
Addresses
Next possible start
used by
address for the
following DMX unit
1 – 8
9
6 – 13
14
1 – 23
24
24 – 46
47
1 – 27
28
486 – 512
–
1 – 69
70
444 – 512
–
.
.
INTERNATIONAL GmbH & Co. KG. No part of this instruction manual may be
®
7) Set the same start address and the same num-
ber of channels for all other MINICUBE-60 to
be controlled synchronously .
8) DMX control of the moving head will now be
possible . The DMX functions can be found
on pages 20 – 22 . If the moving head does
not receive any DMX control signal, it will go
to the independent mode (chapter 5) .
Hint: When two or more MINICUBE-60 are controlled
via the same start address, invert the direction of move-
ment on one or more moving heads (refer to page 3,
menu item "Pan Inverse") . Thus, when a pair of moving
heads is used, their rotating arms will move in opposite
directions (mirror-inverted movements) .
7 Specifications
Data protocol: . . . . . . . DMX 512
Number of
DMX channels: . . . . . . 69, 27, 23 or 8
Light source
6 × beam LED: . . . . . 10 W RGBW LED from
12 × LED strips: . . . . 6 × 5050SMD (RGB)
Pan / TIlt angle: . . . . . . . Pan 560°, Tilt ∞
Ventilation: . . . . . . . . . integrated fan
Ambient temperature: 0 – 40 °C
Power supply: . . . . . . . 230 V/ 50 Hz
Power consumption: . . 175 VA
Dimensions: . . . . . . . . 27 × 35 × 20 cm
Weight: . . . . . . . . . . . 6 kg
Connections
DMX: . . . . . . . . . . . XLR, 3 poles
Mains: . . . . . . . . . . . Powercon
Subject to technical modification .
OSRAM
beam angle: 10°
(1 × In, 1 × Out)
(1 × In, 1 × Out)
11