INSTALLATION INSTRUCTIONS (continued)
 
INSTALLING THE UNIT
 
 
Secure the hood to the recommended height of 30" above the cooking surface.  
   
  
 
 
 
Stud
 
 
 
blockings
 
 
Adjust  the 
support 
frame 
 
extensions
 
 
 
 
6. Slide the upper chimney cover over the completed support frame and fasten with two "F" bolts to the 
upper support frame (see Figure 3).  
 
 
 
 
 
 (continued)   
1.
  
 
 
Secure the 
upper support 
 
frame
 
 
2.
  
3.
  
4.
Insert the lower 
support frame 
with extensions 
  
 
 
5.
 
Figure 3
  
     23 
Align upper support frame with holes in ceiling. Mount 
the  upper  support  frame  to  the  ceiling  using  four  "A" 
screws (for sheet rock only). Make sure that the upper 
support  frame  is  securely  fastened  to  the  joist  or 
support  in  the  ceiling.  Attach  support  frame  to  ceiling 
using anchors recommended for your type of ceiling:  
• Sheet  rock  ceiling:  Attach  support  frame  to  ceiling 
joists or stud blockings if possible. If ceiling joists or 
stud blockings are not available, it is required to build 
a supporting structure behind the sheet rock for best 
weight support.  
Concrete ceiling: Use concrete sleeve anchor.  
Wood ceiling: Use at least 4" long wood screws.  
Position  the  support  frame  extensions  at  the  inside 
corners  of  the  support  frames,  adjust  and  mark  each 
support  frame  extension  as  necessary  to  achieve  the 
proper height for the range hood to be set away from 
the cook top.   
Fasten  the  support  frame  extension  onto  the  lower 
support frame using four "B" bolts and "C" nuts as it is 
shown  in  Figure  3.    Repeat  this  step  for  rest  of  the 
support frame extensions.  IMPORTANT: Always use first 
and second holes on the support frame extensions.  
Calculate  the  height  of  the  duct  tube  and  extend 
approximately  6  inches  longer  than  required,  connect 
the upper end of the duct tube to the vent system.  
Position  the  lower  support  frame  with  support  frame 
extensions  to  the  upper  support  frame,  fasten  each 
extension with four "B" bolts and "C" nuts as shown in 
Figure 3.  
  