9. CLEARING THE REMOTE CONTROLS
AND ALL SETTINGS

9.1. Clearing the memorised remote controls - Fig 33

Press the "PROG" button (7 s) until the "PROG" indicator light flashes.
Causes all stored remote controls to be cleared.

9.2. Deleting all settings - Fig. 34

Press the "SET" button (7 s) until the "POWER" indicator light flashes
slowly.
Clears the auto-programming and resets the default values for all
parameters.
10. LOCKING THE PROGRAMMING
BUTTONS - FIG. 35
Warning
The keypad must be locked to ensure the safety of the users.
Failure to follow this instruction may result in serious injury, e.g.
due to crushing by the gate.
Press the "SET", "+" and "-" buttons together.
The programming (auto-programming, parameter setting) is locked.
To access the programming again, repeat the same procedure.

11. DIAGNOSTIC AND REPAIRS

11.1. Diagnostics

POWER indicator
: First time the unit is switched on,
: Programming in progress
: Electronic fault (motor thermal cut-out,
: Programming complete
Photoelectric cells
: Normal operation
indicator light
: Detection in progress
Safety edge indicator
light
Complete opening
operation indicator
light
: Control activated
Pedestrian opening
operation indicator
light

11.2. Safety device failure

In the event of a malfunction of the photoelectric cells or the safety edge, a
key contact connected between terminals 12 and 13 allows the gate to be
controlled in dead-man mode after 3 minutes.
9
programming not carried out
etc.)
Auto-test in progress
Permanent fault

12. TECHNICAL DATA

GENERAL SPECIFICATIONS
Power supply
Max. power consumption
Programming interface
Climatic operating conditions
Radio frequency
Number of memorisable channels:
One-way controls (Keygo io, Situo io,
etc.)
CONNECTIONS
Programmable
Type
safety input
Compatibility
Wired control input
Offset lighting output
Orange light output
Controlled 24 V power supply output
Safety input tests output
Accessories power supply output
Offset aerial input
Backup battery input
OPERATION
Forced operating mode
Independent remote lighting control
Timed lighting (after movement)
Automatic closure mode
Orange light warning
Pedestrian opening control
Gradual starting
Slowing zone when opening and
closing
220-230 V - 50/60 Hz
600  W (with offset lighting,
500 W)
4 buttons - 12 indicator lights
- 20°C/+ 60°C - IP 44
868 - 870 MHz
< 25 mW
Complete/pedestrian opening
control: 30
Auxiliary output control: 4
Dry contact: NC
TX/RX photoelectric cells - Bus
cells - Reflex photocell - Dry
contact output safety edge
Dry contact: NO
Dry contact
Max. 230 V - 500 W
• either 5 fluocompact or LED
lights
• or 2 power supplies for
low-voltage LEDs
• or 1 halogen light, max. 500 W
24 V - 15 W
Yes: for possible TX/RX photo-
electric cells auto-test
Yes: possible safety edge
auto-test
Max. 24 V - 400 mA
Yes: compatible with io aerial (ref.
9013953)
Yes: compatible with 9.6 V battery
(part no. 9001001)
Battery life: 24 hours; 3 cycles
depending on the gate
Charging time: 48 hours
By pressing the "+" and "-" but-
tons before auto-programming
Yes
60 s
Yes: short or long closure
time-delay
2 s in sequential mode with
closure time-delay
Yes
Yes
Programmable: 3 values possible