Programming The Remote Controls; Memorising The Keygo Io Remote Controls; Memorising 3-Button Remote Controls - SOMFY ELIXO SMART io Manuel D'installation

Masquer les pouces Voir aussi pour ELIXO SMART io:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Elixo Smart io
P3
Obstacle detection sensitivity
Values
1: Very weak
2: Weak
3: Standard
4: Maximum
Comments
Warning
If the setting is changed, the installer must
check that the obstacle detection system com-
plies with appendix A of standard EN 12 453. If
necessary, install a safety edge and check that
compliance is obtained.
Failure to follow this instruction may result in
serious injury, e.g. due to crushing by the gate.
P4
Photoelectric cells
Values
1: Active
2: BUS
3: Active with auto-test via power supply switching
4: Inactive
Comments
1: safety device without auto-test; it is essential to
check that it is operating correctly every 6 months.
2: bus cells application.
3: the auto-test is run on the device for each operating
cycle via power supply switching.
4: the safety input is not taken into account.
Warning
If P4 = 4, the motorisation cannot be operated
in automatic mode and in-view control of the
motorisation is mandatory.
Px
Safety edge auto-test
Values
1: Without auto-test
2: With auto-test
Comments
1: safety device without auto-test; it is essential to
check that it is operating correctly every 6 months.
2: the auto-test is run on the device for each operating
cycle via the test output.
Copyright © 2018 SOMFY ACTIVITES SA. All rights reserved.
8. PROGRAMMING THE REMOTE
CONTROLS

8.1. Memorising the Keygo io remote controls

8.1.1. Via the programming interface
1) Press the "PROG" button for 2 s.
The "PROG" indicator light is permanently lit.
͉
͉
Pressing "PROG" again allows you to move onto memorisation of the
next function.
2) Briefly press the outer left and right buttons on the remote control
together.
3) Briefly press the button selected to control the function (complete
opening, pedestrian opening, control of Aux 230 V output).
Complete opening control - Fig. 14
Pedestrian opening control - Fig. 28
Aux 230 V output control - Fig. 29
8.1.2. By copying a previously memorised Keygo io
remote control - Fig.30
This operation is used to copy the programming from a previously
memorised remote control button.
1) Press the outer left and right buttons on the previously memorised
remote control simultaneously until the indicator light flashes.
2) Press and hold the button to be copied on the previously memorised
remote control for 2 seconds.
3) Briefly press the outer left and right buttons on the new remote control
together.
4) Briefly press the selected button to actuate the motorisation on the
new remote control.
Key:
Keygo io A = "source" remote control already memorised
Keygo io B = "target" remote control to be memorised

8.2. Memorising 3-button remote controls

8.2.1. A via the programming interface - Fig. 31
1) Press the "PROG" button for 2 s.
The "PROG" indicator light is permanently lit.
͉
͉
Pressing "PROG" again allows you to move onto memorisation of the
next function.
2) Press "PROG" at the rear of the 3-button remote control to memorise
the function.
The "PROG" indicator light flashes for 5 s.
8.2.2. By copying a previously memorised 3-button
mono-directional io remote control - Fig.32
A = "source" remote control already memorised
B = "target" remote control to be memorised
8.2.3. Function of the 3-button remote control buttons
Function
Complete
Complete
opening
opening
Pedestrian
Complete
opening
opening
Aux 230 V
Aux. output ON
my
Stop
Complete
closing
If the gate is open
Complete
or closed à
closing
pedestrian opening
Otherwise à stop
Aux. output OFF
EN
8

Publicité

Table des Matières
loading

Table des Matières