26 - Element and Control Setting
EN
Control knobs and power level adjusting
The placement of each knob corresponds to the placement of the induction element that it controls.
To turn on any, PUSH and TURN the knob clockwise to the required setting, of the according cooking zone can be increased
between a minimum of 1 to a maximum of 9. To reduce the power of the cooking zone again it is necessary to turn the knob
anticlockwise.
The current power level is displayed on the display unit of the hob.
34
ELEMENT AND CONTROL SETTING
Melting function
If the knob is turned clockwise from zero position the first "power level" reached is the melting function.
The according 7 segment display unit shows this "u" symbol. The melting function is used to heat up
the bottom of the pot (40°C inside the pot). This function is used to melt food. The maximum time for
using the melting function is limited to 2 hours.
Warming function
The warming function is the second "power level" which will be selected when turning the knob
clockwise. The according 7 segment display unit shows this "U" symbol. The warming function is used
to heat up the bottom of the pot to 70°C (65°C inside the pot). Using this function the food can be kept
warm or it can be used to warm up food gently.
The maximum time for using the warming function is limited to 2 hours.
Automatic Heat Up time function
To activate the heat up time automatic press and turn the knob counterwise in overwind position "A"
until a beep sounds and the "A" symbol on the display starts blinking waiting for an input. Within the
next 10s a valid cooking level has to be selected from 1 to 8.
This will be the cooking level after a defined time of higher power output at level 9. The 7 segment
display alternates between "A" and the selected cooking level.
If the knob is turned clockwise by selecting level 0, level 9, (warming, melting) or in any position
counterwise the automatic heat up function will be turned off.
Booster function
To activate the boost function press and turn the knob clockwise in overwind position "P" until a beep
sounds. The symbol is as shown "P" and will be displayed. After 10 minutes the boost function will be
automatically switched off and the "P" is not shown on the display anymore and the induction control
will be set automatically at level 9.