With Dip 2 OFF = auto close disabled, the open, close and stop commands are sent with the remote control or button.
With the door closed, hold down MEMO RX and press the desired transmitter button within 5 sec.; the courtesy lamp will
flash to confirm memorization.
Repeat for each separate transmitter. Up to 20 different codes can be stored in this way.
TO DELETE A TRANSMITTER: hold down MEMO RX until the courtesy light turns on, then press the transmitter button;
the courtesy light flashes 3 times to confirm the deletion - now release the MEMO RX button.
RESETTING MEMORY: resets memory by deleting all memorized codes - hold down MEMO RX until the courtesy light
goes out
- the courtesy light flashes 9 times to confirm that the memory has been reset - now release the MEMO RX button.
COURTESY LIGHT SIGNALS
no FLASH = transmitter to memorize.
1 FLASH = transmitter memorized.
2 FLASHES = a previously memorized transmitter is being re-memorized.
3 FLASHES = a transmitter has been deleted.
4 FLASHES = in delete mode, transmitter not memorized.
5 FLASHES = memory full.
9 FLASHES = all memorized codes deleted.
Tilt-up doors
The DUMPER automation can also be installed to tilt-up doors; in this case you must install the AU.C25 adapter to the
door as shown in figure 17.
In order to join the bent arm of the DUMPER to the straight arm provided with the accessory AU.25 it is necessary to cut
the bent drive as shown in picture number 17 and using the straight arm as template, drill 2 holes of 6 mm of diameter and
so join the 2 arms (the screws are not provided).
Emergency battery kit
An emergency battery kit is available (code DM.BT) to allow the automation to work even during mains power failures.
Fit the batteries in their compartments and hook them up as shown in Figure 18.
TECHNICAL DATA
Power
Motor feed
Power draw
Standby power draw
Traction/thrust
Maximum stroke
Accessory power
Opening speed
Closing speed
Maximum load
Intermittency
Operating temperature
Protection rating
Noise level
Weight
18
MEMORIZING TRANSMITTERS

OPTIONAL ACCESSORIES

DUMPER 7
115 - 230V AC 50/60 Hz
24Vdc
1 A
1W without accessories
3W with accessories
700 N
2700 mm - 3700 mm
24 V =/O.5A max
0.12 - 0.20 m/s
0.12 - 0.20 m/s
9 sqm
Intensive Use
-20°C/+50°C
IP 10
>60dB
1.6 kg
DUMPER 10
115 - 230V AC 50/60 Hz
24Vdc
1,5 A
1W without accessories
3W with accessories
1000 N
2700 mm - 3700 mm
24 V =/O.5A max
0.12 - 0.20 m/s
0.12 - 0.20 m/s
12 sqm
Intensive Use
-20°C/+50°C
IP 10
>60dB
1.6 kg