Cooling Fan
Defrosting
Compresor
7.6. OPERATION OF CONTROL PANEL
7.6.1. CHANGING THE SET VALUE
• In order to display the set value, press and imme-
diately release the [SET/MUTE] button.
• Press and hold the [SET/MUTE] button for at least
1 seconds to change the set value. The current set
value will be displayed.
7.6.2. SETTING THE DEFAULT PARAMETERS
To reset the default parameters:
• disconnect power from the instrument;
• reconnect power while holding the [SET/MUTE]
and [DOWN/DEFROSTING] buttons;
• the display will show the message "CF";
7.6.3. TURN ON/OFF CONTINUOUS CYCLE
To turn ON/OFF continuous cycle, press and hold the [UP/SWITCH] + [DOWN/DEFROSTING] buttons for more
than 3 seconds. "CC" will be displayed.
7.6.4. MANUAL DEFROSTING
To start the manual defrosting, press and hold the DEF [DOWN/DEFROSTING] button for more than 3 sec-
onds.
7.7. ALARMS
Alarm
EE
EtC
HI
LO
IA
cht
dOr
Illuminated
Light
Blinks
Illuminated
Light
Blinks
Illuminated
Light
Blinks
Fan activated
The start of fan is delayed due to
external shut-off; other procedure is in progress
Defrosting in progress
The start of defrosting is delayed due to external
shut-off; other procedure is in progress
Compressor on
The start of Compresor is delayed by protective
procedure
• To change the set value, press the [UP/SWITCH]
or [DOWN/DEFROSTING] arrows. To store the
new set value, press the [SET/MUTE] button again
or wait 15 seconds.
• after a few seconds the instrument starts oper-
ating with the default configuration. Any different
parameter settings will need to be updated.
Warnings: running this procedure overwrites any
custom parameter settings.
Error
Unit parameter error
Clock alarm
Maximum temperature alert
Minimum temperature alert
External alert
Dirty condenser alarm
Door opened
EN