Montageanleitung / Instructions de montage
Installation Instructions / Montagehandleiding
Indicaciones de montaje
Troubleshooting
If ...
The energiser is not pulsing
and the first red Indicator
light is flashing
The first red Indicator light is
flashing and other indicator
lights are on
The energiser is pulsing slow-
ly and has a reduced output
voltage
The warning light flashes and
the acoustic alarm sounds
The output voltage digits
(large digits on the LCD dis-
play) flash 1.0 kV
P4600/P6000 only: The first
red Indicator light is
illuminated permanently
72
This means that ...
The battery connections may be faulty. Check all battery
connections. Check the battery voltage immediately using the
battery test setting. See "Battery Test setting" on page 57
The energiser has a fault. If the display persists and does not
return to normal, contact your service agent for advise.
The battery voltage may be low and the energiser has rever-
ted to Slow Speed and Low Output Power in order to preserve
the remaining power and energy in the battery.
The energiser detected a sudden load rise at the fence. Turn
off the energiser, locate and eliminate the fault and turn the
energiser back on.
The fence voltage is below 1000 V. There is a serious fault
on the fence line. See "How do I locate faults?" in "Frequently
asked questions/Troubleshooting on page 67.
The earth monitor voltage is too high. Use the earth monitoring
feature to monitor the earth. See "Earth monitoring" on
page 56.