patura P 4500 Notice D'emploi page 60

Masquer les pouces Voir aussi pour P 4500:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Montageanleitung / Instructions de montage
Installation Instructions / Montagehandleiding
Indicaciones de montaje
Lights
Notes:
• In extreme temperatures, these guidelines may not apply.
• After 30 seconds the display will switch from the battery test results to the fence voltage
P4600 and P6000 only:
At the switch position "Battery test" the digital display shows the battery voltage. When the voltage
is outside the normal range, the battery symbol in the display flashes twice per second.
We recommend to recharge the battery immediately. During normal
operation at the following switch positions
battery symbol on the display flashes when the battery voltage is too low.
We recommend recharging the battery immediately.
60
Input supply voltage
Above 17,0 V
Battery overcharged or wrong type of battery
12,6 - 17, 0 V
Full battery charge voltage (80–100%):
·
12,3 - 12,6 V
Medium battery charge voltage (50–80%):
·
12,0 - 12,3 V
11,7 - 12,0 V
Low battery charge voltage (20–50%):
·
·
11,2 - 11,7 V
Bad battery charge voltage (10–20%):
·
·
Below 11,2 V
Very bad battery charge voltage: (0–20%):
·
·
,
Earth monitor voltage
Battery charge level
No action required
No action required.
Monitor battery voltage
Recharge the battery to avoid long-term damage
to the battery.
Recharge the battery immediately
Energiser will automatically revert to Slow Speed
and Half Power.
Recharge the battery immediately
Energiser will automatically shutdown (deep
discharge protection) to save energy. The last
green LED flashes once per second
,
and
the
Battery symbol
Input supply
voltage

Hide quick links:

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

P 4600P 6000145410145450145602

Table des Matières