No.
Error messages
22
LAMP_B HOUSE DETACHED
23
REAR COVER DETACHED
24
LAMP_A POWER SUPPLY UNIT
ALERT
25
LAMP_B POWER SUPPLY UNIT
ALERT
26
LAMP_A IGNITION FAILURE
27
LAMP_B IGNITION FAILURE
28
CPU ALERT
29
MUTING OFF FAILURE
DOUSER OPEN FAILURE
30
INPUT BOARD FAN FAILURE
31
REAR FAN ALERT
32
LOW REAL TIME CLOCK
BATTERY
33
FPGA CONFIG FAILURE
34
IIC FAILURE
35
LAMP A ALERT
36
LAMP B ALERT
37
LAMP A WARNING
38
LAMP B WARNING
39
DATA LOAD FAILURE LENS
POSITION SENSOR
40
PS FAN FAILURE
32
GB
Error Messages
Meaning
The projection lamp house of Lamp B
is detached, or the harness is
disconnected or down.
The rear cover is open, or the harness
is disconnected or down.
Temporary high temperature or some
trouble with the power (ballast) of
Lamp A
Temporary high temperature or some
trouble with the power (ballast) of
Lamp B
Lamp A does not turn on.
Lamp B does not turn on.
Trouble with the main CPU (IC301)
on the SY-321. Serious trouble
Trouble with opening/shutting of the
shutter, or the harness is disconnected
or down.
Trouble with the axial fan next to the
INPUT A/B/C/D boards, or the
harness is disconnected or down.
Trouble with the huge axial bfan at the
rear, or the harness is disconnected or
down.
The RTC battery (BT201) for the SY-
321 board should be replaced.
The internal line of the projector does
not function properly.
The internal line of the projector does
not function properly.
The time used for Lamp A exceeds the
recommended time for replacement.
The time used for Lamp B exceeds the
recommended time for replacement.
The time used for Lamp A exceeds
80% of the recommended time for
replacement.
The time used for Lamp B exceeds
80% of the recommended time for
replacement.
Failure of the lens position adjustment
to the registered setting.
Trouble with the fan for PS converter,
or the harness is disconnected or
down.
Remedy
Check the attachment screw on the projection
lamp house of Lamp B or the harness.
Close the rear cover securely.
If the error message is still displayed, check the
projector is installed properly, or replace the
power supply unit for Lamp A.
If the error message is still displayed, check the
projector is installed properly, or replace the
power supply unit for Lamp B.
Replace Lamp A.
Replace Lamp B.
Turn off the power, then turn it on again. If the
error message is still displayed, replace the SY
board with a new one.
Check the motor of the shutter or replace it with a
new one.
Check the connection between the fan located on
the front of the board shield and the SY board, or
replace the fan with a new one.
Check the connection between the rear fan and
the SY board, or replace the rear fan.
Replace the BT201 RTC battery for the SY-321
board with a new one.
Turn off the power of the projector, then turn it on
again.
Turn off the power of the projector, then turn it on
again.
Replace the projection lamp of Lamp A with a
new one.
Replace the projection lamp of Lamp B with a
new one.
Place an order for the projection lamp.
Place an order for the projection lamp.
Check the projector is installed properly, then
redo the setting again. If the error message is still
displayed, inspect the lens and have it repaired if
necessary.
Check the fan located at the upper part of the PS
converter is connected to the SY board correctly,
or replace the fan with a new one.