Télécharger Imprimer la page

Anselmo Cola ENERGYCA Manuel D'installation, D'utilisation Et D'entretien page 44

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Hydraulic diagram - heating pellet stove ref. COLA 20-25kW-07-2011
Heating pellet stove
Pellet heating
chamber - 2011
Pt=20-25 kW
Int. volume 23.5 lt.
KEY
Drain cock
Pressure sensor / Pressure gauge
Circulating pump
Membrane pressure vessel
Shutoff valve / Cock
Non-return valve
2.10 Emergency
Suitable fire-prevention devices should be arranged for any eventuality.
In case of a fire, proceed as follows:
- Immediately disconnect the plug;
- Extinguish the fire using suitable fire-extinguishers;
- Call the fire department immediately;
- Do not use jets of waters to extinguish the fire.
3 STOVE SAFETY
3.1 Safety distance from flammable materials
To prevent the risk of fire, stove positioning must respect a minimum distance from flammable materials, according
to that given in the technical table of the manual and on the dataplate.
Pay attention to the type of floor: for delicate and flammable materials it is advisable to use plates in steel or
toughened glass as a support base (see section 2 - Transport and Installation). In case of particularly fragile objects
such as furniture, curtains or sofas, increase the stove distance considerably.
Thermostat
T > 85°C
Circuit / heating chamber air ven
Safety valve P max 3 bar
Safety sensor T > 85°C
Water temperature sensor
Circuit pressure sensor
Valves to be included in system
during installation – not supplied
with the unit
44
Heating DELIVERY
male 1"
Heating DELIVERY
male 3/4"
OVERPRESSURE WATER
DISCHARGE F1/2"
Heating RETURN
male 1"
Heating RETURN
3/4"
male
Water supply F1/2"
Pmax 2 bar
Arrangement
PLUMBING CONNECTIONS on back of
stove

Publicité

loading