1.4 Technical description
The stove works exclusively on pellets, providing healthy and safe heat in the room. The stove's automatic control
systems guarantee optimum heat output and complete combustion; there are also safety systems to guarantee safe
operation for the stove parts and for the user.
When correctly installed, the unit works in any outside climatic conditions, and in any case in critical conditions
(strong wind, frost, etc.) the safety systems can cut in, shutting down the stove.
Structure
Combustion chamber
Heat output nominal - reduced
Hourly consumption Nom.output- Red. output
Efficiency Nom.output- Red. output
Fume outlet temperature Nom.output- Red. output
Emission with 13 % O2 Nom.output- Red. output
Flue gas flow
Dust emission with 13 % O2 - Nominal output
Min. draught
Fume outlet pipe
Air inlet pipe
Electrical power supply
Electrical power input
Min. safety distance rear - right/left side - floor
Dimensions (mm)
Stove weight
Hopper capacity
Max. heatable volume
* Pellet consumption can vary according to the type of pellets used and their preservation.
** Considering 35 W/h per m3. The building's energy requirement can vary according to the
insulation, type and climatic zone.
steel and cast iron
steel and cast iron
Nom. output
11 kW
Nom. output 2.55 kg./h*
Nom. output 90.86 %
Nom. output 166.3 ° C
Nom. output 0.01 %
Nom. output 7.15 g/s
8.2 mg/m3
10 - 14 Pa
Ø 80 mm
Ø 50 mm
230V/50 Hz
420 W max. in lighting stage
140 W for normal operation
200 – 300 – 0 mm
H x W x D = 980 x580x546 mm steel vers.
H x W x D = 980 x509x546 mm ceramic vers.
118 kg ceramic version
107 kg sheet metal version
30 litres (~21 kg)
251 m3 **
37
Red. output 3.66 kW
Red. output 0.81 kg./h.*
Red. output 95 %
Red. output 86.7 ° C
Red. output 0.01 %
Red. output 2.7 g/s
ORION H 2011