Télécharger Imprimer la page

Ferroli T 18 Manuel D'installation, D'utilisation Et D'entretien page 49

Publicité

Les langues disponibles
  • FR

Les langues disponibles

- Initial load
Setting this function allows activation of gearmotor operation, with the stove off or cold, for pellet preloading of 90
sec. It starts with button P1 and stops with button P4.
- Pellet type
With the function on, press the buttons P1 or P2 to increase or reduce pellet loading to optimise consumption and
combustion, depending on the type of pellets used.
- Initial load auger 2
Setting this function allows activation of gearmotor operation relevant to the supplementary hopper for a fixed time. It
starts with button P1 and stops with button P4.
4.6.3 Menu 03 - User setting
With this menu it is possible to carry out the following settings:
- Language
With this selection it is possible to select the dialogue language from those available entered in the menu, and
namely: ITALIAN - FRENCH - ENGLISH - GERMAN – SPANISH
- Buzzer
With this selection it is possible to activate/deactivate stove acoustic signalling.
- Lighting
With this selection it is possible to change the brightness of the backlit display from a minimum of 0 to a maximum of
100.
- Heating Delta
With this selection, it is possible to set:
- the range between the SET temperature and the actual stove shutdown temperature;
- the range between the SET temperature and the actual stove relighting temperature.
This range can be set from a min. of 0.5°C to a max. of 20°C depending on the customer's needs and/or the type of
system.
- Boiler/Puffer Delta
With this selection, it is possible to set:
the range between the SET temperature and the actual stove relighting temperature.
This range goes from a min. of 0.5°C to a max. of 20°C depending on the customer's needs and/or the type of
system.
- Pellet level
With the selection set to ON, the no pellets signal can be managed with:
- a message on the panel 'NO PELLETS';
- management of a supplementary pellet hopper (available on request).
With the selection OFF, the possible supplementary hopper is disabled and no message appears on the panel.
- DHW control
The selection ON allows to manage DHW from the storage tank or heat exchanger through the signal from the
thermostat or flow switch.
The selection EST allows domestic hot water to be controlled in the summer (with heating off), via the signal from
thermostat or probe. Selecting this item enables operation of just the DHW branch; standby is forced to ON and
post-circulation follows that set in the menu M-6-9.
The summer function can be displayed only if the menu M-6-8 is set to T-BOILER or S-BOILER.
4.6.4 Menu 04 – stove status
With this selection it is possible to display the instantaneous stove status giving the operating status of the various
devices connected to it; various pages placed in succession are available for monitoring.
4.6.5 Menu 05 – settings by technician
This selection is reserved for the authorised technician of the service centre.
Modification of the technical parameters of menu 09 must be done by authorised and competent personnel; any
changes made at random can cause serious damage for which Manufacturer declines any liability.
49
T 18

Publicité

loading