Télécharger Imprimer la page

Ferroli T 18 Manuel D'installation, D'utilisation Et D'entretien page 44

Publicité

Les langues disponibles
  • FR

Les langues disponibles

The Figure opposite describes the meaning of the status indicators in
the left part of the display.
Activation of one of the segments on the display signals activation of
the corresponding device according to the list opposite.
4.3 Lighting
4.3.1 Check before lighting
Before lighting the stove:
- make sure to have read and understood the information given in the manual;
- follow the oral instructions on operation of the unit provided by the installer prior to use.
- the hopper must be filled with pellets;
- the combustion chamber must be clean;
- the brazier must be completely free, cleaned of any combustion residuals and correctly fitted in the brazier
holder;
- check hermetic closing of the ash box and fire door;
- check the connection of the power cable and switching to ON/1 of the switch located on the back of the stove.
- check opening of the delivery and return shutoff valves as well as the water circuit pressure.
- At first startup, remove all the components that could burn (instructions/label) from the stove firebox.
- Any lighting done after long idle periods requires the removal of any residual pellets that have remained inside the
hopper, in being damp fuel no longer suitable for combustion, and complete cleaning of the combustion chamber.
4.3.2 Startup stage
To light the stove, press the button 'P4' for 3 seconds: the message 'START' will appear on the display.
This stage is automatic and managed entirely by the electronic controller without the possibility of changing the
parameters.
Alternatively the stove can be lit by pressing the buttons P4 and P5 together for 3 seconds. The message
AWAITING REQUEST appears on the display. With this mode the stove switches to standby status and carries out
the lighting-start stage only if a request for heat is recognised, e.g. to heat the water or for DHW (if available).
Dialogue box
The stove carries out the startup stages in sequence
according to the procedures defined by the
parameters that manage levels and times, reaching
the work condition unless anomalies or alarms
occur, according to the following table:
Clock
Storage tank-Puffer H
Water temperature
0 temperature
2
Button 'P4'
Status
OFF
START - PREHEAT
PELLET PRELOAD
AWAITING FLAME
PELLET LOADING
FIRE PRESENT
WORK
WORK MODULATE
BRAZIER CLEANING
WORK
FINAL CLEANING
44
External contact
Chrono
Electrical element
Auger
Fume extractor
DHW circuit activation
HEATING circuit activation
ALARM
Devices
Fume
igniter
auger
extr.
OFF
OFF
OFF
ON
ON
OFF
ON
ON
ON
ON
ON
OFF
ON
ON
ON
OFF
ON
ON
OFF
ON
ON
OFF
ON
ON
OFF
ON
ON
OFF
ON
ON
OFF
ON
OFF
exch.
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
-
T 18

Publicité

loading