1.4 Technical description
The stove works exclusively on pellets and enables easy installation with the heating system. The stove's automatic
control systems guarantee optimum heat output and complete combustion; there are also safety systems to
guarantee safe operation for the stove parts and for the user.
When correctly installed, the unit works in any outside climatic conditions, and in any case in critical conditions
(strong wind, frost, etc.) the safety systems can cut in, shutting down the stove.
The stoves model ENERGYCA 30 – ENERGYCA 30S with nominal power of 28 kW ensures a maximum heatable
volume of 800 m3, considering the coefficient of a building's energy requirements equal to 35W/m3, and may vary
depending on the insulation, type and climatic zone which are important variables for the correct choice of unit. For
technical data, refer to the table on page10 - 12.
ENERGYCA 30 - ENERGYCA 30S pellet heating stove dimensions
Key:
A - Power cable connection
B - Combustion air inlet
C - Overpressure water discharge (1/2" female - 3 bar)
D - Water system connection
E - System return (1" male )
F - System delivery (1" male )
G - Fume exhaust pipe connection D 100 mm
H - Control panel model F047
I - Pellet hopper door
L - Adjustable feet
M - Turbulator shaker handle
N - Optional DHW delivery ( 3/4" M – PUMP _ ½" M – EXCHANGER )
O - Optional DHW return ( 3/4" M – PUMP _ ½" M – EXCHANGER )
P - Supplementary delivery connection without pump (1" male)
R - Overpressure water discharge (1/2" female - 3 bar)
41