Anleitung_NBH_2000_SPK7:_
the minimum distance to the housing, i.e. the
installation height, has to be measured from the
top of the skirting.
(Fig. 7) Remove the securing screw (F) for the
wall holder (10) on the top of the heater housing.
Remove the wall holder from the rear of the
housing.
(Fig. 8) Then mark and drill the two fastening
holes Ø 8 mm for the wall holder (4) horizontally
at a distance of 66 mm from each other and at
least 1200 mm above the floor (allow for
skirtings).
Screw the wall holder to the wall.
Hang the bath heater in the wall holder.
(Fig. 9) Mark the hole (H) on the wall. Remove the
bath heater from the wall, drill a hole (Ø 8mm) in
the wall in the position which you have just
marked, and insert a dowel.
Hang the bath heater back in the wall holder and
secure it with the previously removed securing
screw (Fig. 7 / Item F) at the top of the housing.
Finally, screw the connecting part to the wall.
7. Using the equipment
Important! Before using the equipment for the first
time, check that the voltage supply is the same as the
voltage details set out on the rating plate. Read the
safety regulations in section 1.
When the equipment is used for the first time or after
a long period of rest, it may emit an odor for a short
time. This is not a fault.
7.1 Switch for heat output (Fig. 2 / Item 5)
Off setting (A)
Fan setting (B)
Low heat output (C) 1000 W
Maximum heat output (D) 2000 W
Note: One LED in the status indicator shines at low
heat output, two LEDs shine at maximum heat output.
Note: The equipment can be switched on only when
the actual room temperature is lower than the set
room temperature.
7.2 Thermostat control/room temperature control
(Fig. 2 / Item 4):
Switch on the required heat output. Turn the control to
"+" until the required room temperature is reached.
Then turn down the control until you hear a clear click.
The thermostat control switches the heater on and off
automatically to keep the room temperature at an
almost constant level.
This assumes that the heater has sufficient output for
18.05.2011
9:53 Uhr
Seite 13
the room you want to heat. If set to "-", the thermostat
control will switch on the heater at approx. +5°C and
offer at approx. +7°C.
7.3 Towel holders
You can pre-warm or dry towels on the towel holders.
Please make sure that the air outlet at the bottom of
the housing is not obstructed. The heat output is
reduced to 1000 W.
Note: Do not overload the towel holders. They are
designed for a maximum load of 2 kg each.
7.4 Overheating guard
In case of excessive heating the equipment will shut
down automatically. If this occurs, turn off the
equipment, disconnect the mains plug and wait a few
minutes for the equipment to cool. After eliminating
the cause (e.g. a covered air grille), the equipment
can be switched on again. If the overheating guard
triggers repeatedly, please contact ISC GmbH.
8. Cleaning, maintenance and ordering
of spare parts
8.1 Cleaning
Before carrying out any cleaning and
maintenance work the equipment must be turned
off, disconnected from the power supply and
cooled down.
Maintenance and repair work may only be carried
out by an authorized electrical servicing
contractor or ISC GmbH.
Check the power lead at regular intervals for
signs of defects or damage. A damaged power
lead may only be replaced by an electrician or
ISC GmbH in compliance with the relevant
regulations.
Use a damp cloth to clean the casing.
Remove dust with a vacuum cleaner.
8.2 Maintenance
There are no parts inside the equipment which
require additional maintenance.
8.3 Ordering spare parts
Please provide the following information on all orders
for spare parts:
Model/type of the equipment
Article number of the equipment
ID number of the equipment
Part number of the required spare part
For our latest prices and information please go to