Auto-suction stop during wet
suction operation
WARNING:
Do not use for a long time while
the float is at work. Using the cleaner with its float at
work for a long time can cause overheat, resulting in
the cleaner deformation.
WARNING:
Do not pick up foam or soapy
liquid. Picking up foam or soapy liquid can cause
foam to come out of air exit before the float works.
Continuing to using in this condition may cause an
electric shock and breakage of the cleaner.
Auto-suction stop works only when using with the float
and float cage.
The cleaner has a float mechanism that prevents water
from immersing into the motor when picking up more
than a certain amount of water. When the tank is full
and the cleaner no longer picks up water, switch off the
cleaner and empty the tank.
Locking or unlocking the caster
1
► 1. Caster 2. Stopper lever 3. FREE position
4. LOCK position
Locking the caster is convenient when storing the
cleaner, stopping the work on the way and keeping the
cleaner still.
To operate the stopper, move it by hand.
To lock the caster with a stopper, lower the stopper
lever and the caster no longer will rotate. To release the
caster from the locked position, raise the stopper lever.
NOTE: When moving the cleaner, make sure that
the caster is unlocked. Moving the cleaner with the
caster in the locked position may cause damage to
the caster.
3
4
2
Carriage handle
When carrying the cleaner, carry it by holding the han-
dle on the head. The handle is retractable at the head
when not in use.
ASSEMBLY
CAUTION:
Always be sure that the tool is
switched off and the battery cartridge is removed
before carrying out any work on the tool.
CAUTION:
Always wear dust mask during
assembly or maintenance.
Installing the powder filter (HEPA)
and prefilter (for dry dust)
Optional accessory
CAUTION:
Never pick up water or other liq-
uids or wet dusts when using the powder filter.
Picking up such things may cause the powder filter
breakage.
To use powder filter:
1.
Remove the float cage and float by removing the bolts.
1
► 1. Float 2. Float cage
2.
Place the prefilter in the tank while aligning the
mounting position markings.
3.
Mount the damper on the powder filter and then
place them in the prefilter while aligning the mounting
position markings.
8 ENGLISH