4.2 Locating the wall mounted terminals

A
Clearance above grade, veranda,
porch, deck, or balcony
B
Clearance to window or door that
may be opened
C
Clearance to permanently closed
window
D
Vertical clearance to ventilated
soffit located above the terminal
within a horizontal distance of 2 feet
(61 cm) from the center line of the
terminal
E
Clearance to unventilated soffit
F
Clearance to outside corner
G
Clearance to inside corner
H
Clearance to each side of center line
extended above meter/regulator
assembly
I
Clearance to service regulator vent
outlet
4.2 Instructions pour le positionnement
du débouché mural
Canadian installations1
12 in (30 cm)
12 in (30 cm)
12 in (30 cm)
24 in (60 cm)
18 in (45 cm)
6 in (15 cm)
12 in (30 cm)
3 ft (91 cm) within a height 15 ft
(4.5 m) above the meter/ regulator
assembly
3 ft (91 cm)
US installations2
12 in (30 cm)
9 in (23 cm)
9 in (23 cm)
24 in (60 cm)
18 in (45 cm)
6 in (15 cm)
12 in (30 cm)
3 ft (91 cm) within a height
15 ft (4.5 m) above the
meter/regulator assembly
3 ft (91 cm)