8.6 Pressure Differential Valve (Fig. 33, 34)
1. Drain the primary circuit.
2. Undo the screw securing the microswitch to the differential valve.
Allow the microswitch to rest to one side.
3. Undo the pressure gauge capillary nut and heating fl ow pipe nut from
the valve.
4. Prise off the bypass connecting clips and disconnect the heating fl ow
tap. Undo the screws securing the valve to the boiler bottom panel.
Remove the valve.
5. Remove the screws securing the cover from the valve body. Examine
the condition of the diaphragm, spring and pushrod, replacing as neces-
sary.
6. If required the complete valve assembly can be replaced.
7. Examine the sealing washers and 'O' ring on the pipes and capillary,
replacing as necessary.
Fig. 33
8.6 Pressostat différentiel (Fig. 33, 34)
1. Vidanger le circuit principal.
2. Dévisser la vis de fi xation du microrupteur sur le corps de la vanne.
Poser le microrupteur sur un côté.
3. Dévisser l'écrou du capillaire du manomètre et enlever l'écrou de fi xa-
tion de la conduite de chauffage à la vanne.
4. Écarter le collier de maintien du by-pass et le débrancher du robinet de
l'eau de chauffage. Dévisser les vis de fi xation de la vanne sur le panneau
en bas de la chaudière. Déposer la vanne.
5. Enlever les vis de fi xation du couvercle sur le corps de la vanne. Exa-
miner l'état du diaphragme, du ressort et de la tige. Remplacer si besoin
est.
6. Si nécessaire, remplacer la vanne complète.
7. Examiner les rondelles d'étanchéité et les joints toriques sur les con-
duites et le capillaire. Remplacer si besoin est.