Red Smoke /
Red CO LED
Heat LED
All 3 LED's flash together (
fourth flash (
+
only) occurs. This flash pattern is
repeated.
Either the carbon monoxide indicator
or the smoke / heat indicator
are flashing every 10 seconds
Either the carbon
monoxide indicator
or the smoke / heat indicator or both,
are
flashing
18
Amber Fault LED
+
+
) 3 times, then a
or both,
Double flashing
every second
Status
This indicates that the
'Reorganisation Mode' has
been unsuccessful.
This indicates that one of the
alarms has previously been
activated.
An alarm on the network has
developed a fault.
Action required
To exit 'Reorganisation Mode' hold
the 'Locate' button for 5 seconds,
wait a couple of minutes and
then press and hold the 'Locate'
button for 5 seconds to start
'Reorganisation Mode' again.
Please refer to the 'Locate' section
of this manual.
Please refer to the 'Fault Detection'
section of this manual.