MIDI [OUT]: the MIDI connector that transmits the MIDI data generated by the organ.
-
MIDI [THRU]: retransmits the data received by the [IN] port for connection of several MIDI devices
in series.
-
[USB]: two USB connectors. The one on the left is used for connecting to a computer to allow the
instrument's setup programme to be used. The one on the right is for use of an USB stick (not
supplied with the instrument) for use as a mass memory for the organ instead of the internal memory.
For further information refer to chap. 11.
-
[PHONES]: the socket for connecting a headphone set.
18. Cover lock.
19. Coupler controls.
These toe-pistons or tabs controls the couplers of manuals and pedalboard.
20. [TREMULANT] section.
Here you will find the tremulants for the manuals.
21. [CRESCENDO] sweller.
You can use this sweller to select the Crescendo steps which activate a preset series of stops. The step
currently selected is displayed by the additional [CRESCENDO] display (see point 12).
Each Crescendo step is programmable. The procedure for saving them is described in point 14.
22. Swell expression pedals.
The CL / CLV 8 have two swell pedals for continuous control the expression of Manual I and Manual
III. The CL / CLV 7 model has continuous control of the volume of Manual II only.
The swell pedal on the right also incorporates a special lever system for control of the Sustain effect for
the Orchestra voices.
23. Rear connections.
On the back of the organ, there are various connections for making the audio connection to external
speaker systems, and the line and microphone input for use of the organ's internal amplifier.
-
[EXT. +12V DC] connectors: power at +12 Volt can be obtained from these connectors to supply
any VISCOUNT speakers connected to the PROG. OUT. outputs.
-
OUT [GEN. SUB] (General Sub-Woofer): dedicated output for the connection of low-frequency
speakers (sub-woofer).
-
PROG. OUT (Programmable Outputs): the instrument's general line outputs, allowing simulation of the
wind-chests of pipe organs. The signals are distributed over the outputs on the basis of the display function
settings, which allow setting of the type of wind-chest, its size and the position in space of the speakers
used, for each stop. Each output also has dedicated level and equalisation controls.
-
INPUT [L(+R)] / [R]: line inputs which allow other instruments to be played using the organ's
internal amplification. If the source is monophonic use the [L+(R)] connector only.
-
INPUT [MIC]: microphone input allowing amplification of the signal from a microphone.
-
[GAIN]: trimmer for regulating the gain of the input signal received at the [MIC] connector.
WARNING!
This group of connections on the rear is not visible from the outside and the organ's wooden rear
panel has to be removed to access it. Contact qualified staff for this procedure.
24. Switch which enables the power supply on the [EXT. +12V DC] socket.
This socket is located in the back panel (see point 17).