EN
Commissioning
Mounting
2
all dimensions in mm
The ROD4... plus can be fastened using the holes on the rear of the device. For
this, no mounting system is required.
BT ROD4 mounting system
3
all dimensions in mm
It is recommended that the ROD4... plus be mounted with the aid of the BT ROD4
mounting system. The advantage of this mounting variant lies in the exchangeabil-
ity of the device. The device can, in this way, be removed from the mounting sys-
tem and returned at a later time without readjusting the device.
With the aid of the BT ROD4 mounting system, pitches of maximum 8 ° downward
or upward are possible. In addition, the mounting system allows lateral inclinations
of up to ± 4°.
Electrical connection
Safety notices!
Ä
Ä
Ä
NOTICE
UL applications!
For UL applications, use is only permitted in Class 2 circuits in accor-
dance with the NEC (National Electric Code).
NOTICE
Protective Extra Low Voltage (PELV)!
The device is designed in accordance with protection class III for sup-
ply with PELV (Protective Extra-Low Voltage).
20
CAUTION
Before connecting the device, please ensure that the operating
voltage matches the value printed on the nameplate.
Ensure that the functional earth (FE) is connected correctly. Fault-
free operation is only guaranteed if the functional earth is con-
nected properly.
If faults cannot be rectified, take the device out of operation. Pro-
tect the device from accidentally being started.