NOTICE
Degree of protection IP65 is achieved only if the connectors and caps
are screwed into place.
Initial commissioning
The RODsoft / RODplussoft configuration software is required for commissioning.
Download the configuration software from the Internet:
Ä
Call up the Leuze home page: www.leuze.com
Ä
Enter the type designation or part number of the device as the search term.
Ä
The configuration software can be found on the product page for the device
under the Downloads tab.
NOTICE
You can use the RODplussoft configuration software to change the
configuration of interface.
Pin assignment ROD4
4
X1 – SUB-D 15-pin
– Power supply
– Switching outputs/alarm output
– Inputs for field pair changeover
– Restart/reset input
– Configuration connector
Pin No.
Designation
1
GND
2
Restart
3
UB
4
FPS1
5
ALARM1
6
FPS2
Core color
Assignment
Black
Supply voltage ground
Blue
Safe input "restart interlock", reset the
sensor and connection of the restart
button
Red
Supply voltage: +24 V DC
Orange
Switch to detection field pairs
Yellow
Output for object detection in the far de-
tection field and for warning messages
such as "Window soiled" or "Window
heavily soiled" (adjustable).
4-field mode: Output for object detection
in the far detection field 1
Green
Switch to detection field pairs
EN
21