Télécharger Imprimer la page

Leuze electronic ROD4 Mode D'emploi page 23

Scanner laser
Masquer les pouces Voir aussi pour ROD4:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 28
RS 232
Pin No.
Designation
1
NC
2
TxD
3
RxD
4
NC
5
GND/shield
6
RS 232
7
NC
8
NC
9
Reserved
NOTICE
If you would like to work with an RS 422 interface, you must connect
PIN 6 with PIN 5 (GND) by means of a bridge.
RS 422
Pin No.
Designation
1
TxD+
2
TxD-
3
RxD-
4
RxD+
5
GND/shield
6
RS 422
7
NC
8
NC
9
Reserved
Assignment
Not assigned
Data communication, transmission
Data communication, reception
Not assigned
Ground/shielding (to be connected only on the
cabinet side with PE)
Selection RS 232/RS 422.
Selection as interface RS 232: Not assigned
Not assigned
Not assigned
Reserved for test purposes, no wiring
Assignment
RS 422 transmit data
RS 422 receive data
Ground/shielding (to be connected only on the
cabinet side with PE)
Selection RS 232/RS 422.
Selection as interface RS 422: Bridge on pin 5!
Not assigned
Not assigned
Reserved for test purposes, no wiring