Télécharger Imprimer la page

Leuze electronic ROD4 Mode D'emploi page 25

Scanner laser
Masquer les pouces Voir aussi pour ROD4:

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 28
Y3 – Service, M12 socket
Pin No.
Designation
1
NC
2
TxD
3
GND
4
RxD
5
NC
Y4 – RS 232/422, M12 connector
Pin No.
Designation
1
Tx+/TxD
2
Tx-
3
Rx-
4
Rx+ / RxD
5
GND/shield
6
RS 422
7
NC
8
NC
NOTICE
The core colors only apply if Leuze electronic's original connection ca-
bles are used (see operating instructions, chapter "Cables acces-
sories").
IP address
The default IP address on the Ethernet interface is configured ex works as follows:
– IP address: 192.168.60.3
– Subnet mask: 255.255.255.0
Core color
Assignment
Not assigned
White
Data communication, transmission
Blue
Data communication, ground
Black
Data communication, reception
Not assigned
Core color
Assignment
White
Transmitted data
Brown
Green
Receive data
Yellow
Green
Ground/shielding (to be connected only
on the cabinet side with PE)
Pink
Selection RS 232/RS 422
– RS 232: Leave PIN 6 open
– RS 422: Bridge on PIN 5
Not assigned
Not assigned
EN
25

Publicité

loading

Ce manuel est également adapté pour:

Rod4-plusRod4-08 plusRod4-50 plusRod4-56 plusRod4-58 plus