The.MQ.DA.3.does.not.have.any.defined.inlets.or.out-
lets . . You. may. therefore. connect. the. hoses. to. either.
side.of.the.device .
m
All three inlets and all three outlets must be
open.
Please.ensure.that.the.hoses.are.connected.correctly.
to.the.inlets.and.outlets . . The.system.is.not.leak.tight.
if.the.hoses.are.not.properly.connected.to.the.MQ.DA.
3's.aluminium.adapter . . This.can.quickly.lead.to.a.drop.
in.performance . . In.the.worst.case,.water.can.escape.
through. the. connected. hoses. and. cause. extensive.
water.damage . . Only.use.hoses.with.smooth.and.elas-
tic.surfaces.or.spiral.hoses.with.a.matching.specially.
designed.clip.collar .
You.can.control.3.core.drill.holes.directly.with.the.MQ.
DA.3.flow.rate.control.unit . . You.can.also.use.T.and.Y.
pieces.or.a.quad.distributor.to.increase.the.number.of.
controlled.core.drill.holes.to.any.number . . Please.make.
sure.that.the.core.drill.holes.that.are.controlled.by.one.
of.the.device.outlets.are.in.the.same.area .
When. you. use. the. MultiQube. elements,. please. en-
sure. that. any. standing. water. in. the. core. drill. holes.
is.suctioned.off.before.commencing.with.the.drying.
operation . . This.will.reduce.the.drying.times.and.help.
to.rectify.the.water.damage .
m
Particular attention must be paid to the fact
that the device may only be used in vacuum
operation. The screed flooring can otherwise
become damaged when compressed air pres-
sure is applied to individual points!
All.three.inlets.and.all.three.outlets.must.be.open . . It.
must.be.ensured.that.the.nozzles.are.unblocked . . This.
can.otherwise.impair.the.way.the.device.works.to.the.
extent. that. the. connected. compressor. turbine. will.
overheat. and. switch. itself. off . . The. drying. operation.
with.the.other.MultiQube.modules.will.then.be.stopped . .
The. MQ. DA. 3. may. NOT. be. used. in. explosion-prone.
rooms.and.atmospheres .
The. MQ. DA. 3. may. only. be. operated. by. trained. and.
skilled.persons.who.have.been.instructed.in.the.use.
of.the.device.and.who.have.been.trained.in.restorative.
G
drying.technology . . The.operating.instructions.should.
be. consulted . . Schooled. persons. are. those. persons.
who. have. been. instructed. as. to. the. tasks. they. are.
to. perform. and. who. have. been. informed. of. the. po-
tential.dangers.which.can.evolve.if.the.device.is.not.
used.properly.or.the.purpose.for.which.it.was.inten-
ded . . Such. persons. should. receive. proper. training. if.
necessary .
Any.repair.or.maintenance.work.on.electric.parts.may.
only.be.carried.out.by.electrically.qualified.personnel .
On.building.sites,.the.MQ.DA.3.may.only.be.connected.
to.an.electric.1~230.V.50.Hz.16.A.power.supply.with.a.
corresponding.fault.current.circuit.breaker .
In.order.to.avoid.any.faults.from.occurring,.and.de-
pending.on.the.workload,.the.device.should.be.clea-
ned.at.regular.intervals.either.during.or.after.use, .
The.cable.must.be.zcompletely.rolled.up.when.exten-
sion.cables.or.cable.drums.are.used .
03. STARTING UP
1 . . Check. to. ensure. that. the. inlets. and. outlets. are. .
. unblocked . . Remove.any.blockages.or.foreign.ob-.
. jects.from.the.nozzles.or.ducts .
2 . . Connect.the.device.to.the.power.supply .
3 . . Install. all. the. necessary. elements. for. vacuum. .
. restorative. drying. (water. separator,. filter,. com-.
. pressor.and.sound.absorbers) .
4 . . Connect.the.hoses.coming.from.the.core.drill.holes. .
. to.one.side.of.the.MQ.DA.3 .
5 . . Connect.the.hoses.leading.from.the.MQ.DA.3.with. .
. the.water.separator.for.restorative.drying .
6 . . The.device.is.ready.for.operation.as.soon.as.it.has. .
. been.connected.to.the.power.supply.and.only.needs. .
. to.be.switched.on . . Turn.on.the.device . . The.ON/OFF. .
. control.lamp.lights.up . . The.device.starts.to.run .
7 . . A. new. control. cycle. begins. every. 5mins . . The. .
. valves.open/close.and.control.the.suction.current .