Fields of Operation:.
The. MultiQube. flow. rate.
control. unit. is. dimensi-
oned. for. 350. m³/h. and.
can. work. with. vacuum.
pressures.up.to.250.mbar . .
This.makes.it.suitable.for.
work.with.most.compres-
sors. and. other. compo-
nents. for. water. damage.
restoration . . The. MQ. DA3.
can. be. installed. as. the.
bottom. element. of. the.
MultiQube. tower. (fig .1) . .
The. device. can. also. be.
installed. separately. at. a.
suitable. place. near. the.
core.drill.holes.(fig .2) .

04. SHUTTING DOWN

1 . . Use.the.ON/OFF.switch.to.turn.the.device.off.after.
. use . . The.control.lamp.goes.out .
2 . . Remove.the.hose.connections .
Please make sure that there is no water left
m
in the hoses..
3 . . Disconnect.the.plug .
m
Remember to disconnect the plug and the
connection hoses before all cleaning, main-
tenance and repair work and ensure that the
device is disconnected and volt-free.
B - 3

05. CLEANING AND MAINTENANCE

Please.clean.the.device.after.every.use .
1 . . First,.disconnect.the.plug.(1~230.V;.50.Hz).from. .
. the.main.power.supply.and.ensure.that.the.device. .
. does.not.have.any.power . . Remove.the.hose.con-.
. necting.pieces .
2 . . Use.water.and.a.suitable.brush.to.clean.the.hose.ope-.
. nings.of.the.MQ.DA.3 . . Do.NOT.clean.with.a.high.pres-.
. sure.cleaner . . Use.compressed.air,.if.necessary .
3 . . Clean. the. housing. with. a. moist. cloth . . Protect. .
. against.splashes.or.small.sprays.of.water .
4 . . The. housing. of. the. models. in. the. MultiQube. se-.
. ries.are.made.of.ABS.synthetic.material . . Do.NOT. .
. use.chemical.or.solvent-based.cleaning.agents . . If. .
. unsure,.try.out.the.cleaning.agent.on.a.concealed. .
. part.of.the.housing .
5 . . Check.the.connecting.cable.regularly.for.any.signs. .
. of. wear. and. tear. or. damage . . Damaged. cables. .
. must.be.replaced.immediately . . Please.remember. .
. to.check.the.plug.too .
6 . . The.control.valves.of.the.flow.rate.control.unit.are. .
. specially. designed. constructions. that. permit. air,. .
. water.and.foreign.substances.up.to.a.diameter.of. .
. approx . . 15.mm.to.pass.through . . The.valves.on.the. .
. inside.of.the´DA.3.are.not.designed.to.cope.with. .
. a.permanent.flow.of.water.and.foreign.matter . . This. .
. must.be.avoided . . It.is.therefore.necessary.that.the. .
. core.drill.holes.are.cleaned.before.the.restorative. .
. drying.modules.are.used .
7 . . The.control.valves.are.maintenance.free . . There.is. .
. no.need.to.lubricate.them .
8 . . All.maintenance.or.repair.work.may.only.be.car-.
. ried. out. by.TROTEC . . The. warranty. expires. along. .
. with.any.liability.when.such.work.is.carried.out.by. .
. third.parties .
9 . . The.housing.of.the.MQ.DA.3.is.made.of.ABS.syn-.
. thetic.material . . Material.tension.within.the.housing. .
. may.lead.to.slight.discolouring . . Although.such.dis-.
Operating manual – DA3 Flow Rate Control Unit