Trotec MultiQube DA3 Guide D'utilisation page 10

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

TABLE OF CONTENTS
01. General Description . . . . . . . . . . . . . . . . . B - 01
02. Important! Please read first . . . . . . . . . . B - 01
03. Starting Up . . . . . . . . . . . . . . . . . . . . . . . . B - 02
04. Shutting Down . . . . . . . . . . . . . . . . . . . . . B - 03
05. Cleaning and Maintenance. . . . . . . . . . . . B - 03
06. Troubleshooting . . . . . . . . . . . . . . . . . . . . B - 04
07. Interior View of MQ DA 3 . . . . . . . . . . . . . B - 04
08. Technical Data . . . . . . . . . . . . . . . . . . . . . B - 04
09. Circuit Diagram. . . . . . . . . . . . . . . . . . . . . B - 05
This.publication.replaces.all.previous.publications . . No.part.of.this.publication.may.be.
reproduced,.processed.using.electronic.systems,.replicated.or.distributed:.Subject.
to. technical. modifications . . All. rights. reserved . . Names. of. goods. are. used. without.
guarantee.of.free.usage.and.used.for.the.most.part.according.to.the.manufacturers'.
syntax . . The.names.of.goods.used.are.registered.and.should.be.considered.as.such . .
We.reserve.the.right.to.modify.the.design.in.the.interest.of.ongoing.product.impro-
vement,.such.as.shape.and.colour.modifications . . The.scope.of.delivery.may.vary.
from.that.in.the.product.description . . All.due.care.has.been.taken.in.compiling.this.
document . . We.accept.no.liability.for.any.errors.or.omissions . . ©.TROTEC®
01. GENERAL DESCRIPTION
The.DA.3.MultiQube.is.designed.for.commercial.use . .
It.is.a.mobile,.low-noise,.electronically-operated.de-
vice.designed.to.control.vacuum.air.currents . . The.DA.
3. MultiQube. is. designed. and. developed. specifically.
for.carrying.out.vacuum.drying . . The.DA.3.MultiQube's.
automatic. control. system. focuses. the. compressor's.
main.suction.power.on.one.of.three.controlled.drying.
zones.at.a.time.in.regular.intervals.thereby.achieving.
significantly. faster. overall. drying. times. of. as. much.
as. 30. -. 70%. depending. on. the. extent. and. type. of.
damage .
Out.in.the.field,.fresh.water.damage.is.often.characte-
rised.by.inhomogeneous.distributions.of.moisture . . The.
DA.3.air.flow.control.unit.can.reduce.drying.times.to.
a.minimum.by.actively.controlling.three.drying.zones .
The. DA. 3. MultiQube. is. installed. between. the. water.
separator.and.the.drying.zones .
B - 1
02. IMPORTANT! PLEASE READ FIRST
The.DA.3.may.only.be.used.as.a.control.unit.for.va-
cuum.drying.of.screed.or.flat.roofs . . Do.not.use.as.a.
worktop,.a.surface.to.rest.objects.on,.a.stool,.a.step.or.
as.a.substitute.for.a.ladder .
The.DA.3.MultiQube.DA.3.can.be.used.together.with.
all.conventional.compressor.models.to.carry.out.va-
cuum.drying . . It.is.also.perfectly.matched.for.use.with.
the.Trotec.MultiQube.modules.like.the.VE4,.WA4.and.
the.WA4i .
The.MQ.DA.3.flow.rate.control.unit.is.designed.to.dis-
tribute.the.vacuum.current.efficiently.to.the.core.drill.
holes . . When.the.MQ.DA.3.is.used,.the.suction.current.
can.dry.areas.where.moisture.levels.vary.significantly.
after.water.damage.has.occurred.in.a.fraction.of.the.
time.it.would.normally.take.for.these.areas.to.dry .
The.MQ.DA.3.flow.rate.control.unit.is.placed.between.
the.water.separator.and.the.core.drill.holes . . The.de-
vice.does.not.filter.water,.solid.particles,.fine.dusts.or.
other.small.particles . . Such.foreign.substances.do.not.
in.any.way.affect.the.way.the.device.works .
Any.foreign.substances.with.a.diameter.of.more.than.
15.mm.can.clog.or.block.the.control.valve . . It.is.there-
fore. necessary. for. the. drill. hole. to. be. cleaned. tho-
roughly.before.drying.is.carried.out . . This.can.be.done.
using.an.industrial.vacuum.cleaner . .