Using Your SMB CAT5 KVM Switch
Function/Help Page
The "Function/Help" page allows you to set the time intervals for the AutoScan
feature and OSD display time, enable the password security feature, and
program hot keys.
Function/Help Page Keyboard Commands
(F4)
Initiate AutoScan
Navigate to the next field
)
(
(Insert)
Highlight field for editing
(Esc)
Return to the main OSD menu
(F10)
Program Monitor-DDC2 settings to all Server Interface Modules
(Space)
Change options for selected field
Scan
This specifies whether the AutoScan feature is enabled or not. To enable or
disable the AutoScan feature, use the arrow keys to navigate to the "Scan" field
and press the space bar.
Scan Time
This specifies the amount of time the SMB CAT5 KVM Switch remains on a
server before switching to the next server while in AutoScan mode. You may set
the scan time interval to anywhere between 5 and 99 seconds. To change the
scan time, use the arrow keys to navigate to the Scan Time field, type the desired
time interval (in seconds).