Maintenance Of The Chimney And Sweeping; Diagram Showing Installation - deville C07910-A Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
Wall – mounted inverter aquastat (when connected to
a boiler) :
It is to be set up at the top start of the equipment.
The wiring must be realised in compliance with the rules
in effect. Switch off power supply before any operation.
It is strictly forbidden to have the wire cables go inside the
chimney and the hood without them being first insulated
from the fire.
Radiators :
For the appliance to be in proper working order, we
recommend the fitting of a heat exchanger with the
following power ratings :
. 4 kW minimum
. 9 kW maximum
In any case, half of the radiators should not be fitted with
a thermostat.
Piping:
Installed
in
accordance
compliance with the DTU 65-05 and DTU 65-10
standards only to cite both of them.
We advice you not to reduce the start and return sections
of the fireplace.
Pressure of use and feed in water :
Pressure of use: 1,5 bar
Maximal pressure: 2 bars
The installation must be drained.
Draining (Fig. 7) :
The fireplace may be drained after its installation. To do
this, you just have to dismantle the front panel
unscrewing the 4 screws that link it up to the tub. The
draining is then operated by completely unscrewing the
cap located at the bottom of the left tub.
2.9
Maintenance
sweeping
Mechanical sweeping of the smoke flue is obligatory. This
should be done several times a year and at least once
during the heating period. A certificate must be
established by a professional.
Do not install this appliance without a safety valve.
The back boiler must never be isolated from the severing valve, from the heating installation
to which it is joined.
Do not use without water.
Maximum pressure 3 bars.
Fill up the equipment with some anti-freeze because it can not stand the frost.
Regularly start up the safety valve.
with
accepted
trade,
of
the
chimney
____________________________________________________________
RECOMMENDATIONS
____________________________________________________________
Carefully check the condition of the appliance, and more
especially smoke-tightness : seals, fixings, and door and
frame.
Check the condition of the smoke flue and the connecting
pipe ; all fittings should be in good mechanical condition
and be smoke-tight.
Clean the extractor fan inside the hood to get rid of any
dust and if necessary clear the hot air convection system.
In the event of a fault, have the stove or the installation
repaired by a qualified tradesman.
When cleaning the machine, it is necessary to :
Take apart the deflector as pictured, to clean the device.
Deflector in four parts : (Fig. 11a)
Setting up the deflector : (Fig. 11b)
Close the nozzle key
in
Insert the 1st pipe from the back
Set up the 2nd pipe from the front
Place the 3rd pipe from the front
To set up the metal sheet,
lean the sheet up,
let it slide down lying on the heating pipes
To undo the deflector, reverse the setting up operations
mentioned above.

2.10 Diagram showing installation

- Hearth-radiator circuit connection diagram (Fig. 8)
- Hearth-boiler connection diagram (Fig. 9)
- Hearth-radiator circuit and floor heating system
connection diagram (Fig. 10)
and
17
present the sheet,
lift the sheet back up and

Publicité

Table des Matières
loading

Table des Matières