STARTING UP AND PROGRAMMING
1
CONNECTION TO THE GRID
1 Connect the control panel to the electricity supply:
the display should show the sign ?.
Reset (rS): after connecting the electricity power
supply and activating any of the key commands, the
barrier closes to the stopper, with the stopper being
assigned the position "barrier closed".
2
DISPLAY
D1:
Display Menus
D2:
Display Parameters
D3 - D4: Display parameter value
The display goes off following a long period
without pressing any key on the control
board. Press the ENTER key to reactivate.
CHANGE OF TURNING DIRECTION: if, when carrying
out the reset (rS), the barrier opens instead of closing,
it is necessary to change the turning direction by
programming parameter C1 (see "Prior Conditions
Programming (D1= "C")" on page 60).
During programming, ensure there is no
person or object in the radius of action of the
barrier and the operation mechanisms.
Indications during operation:
D1 and D2:
CL
(static)
Barrier closed
CL
(flashing)
Barrier closing
OP
(static)
Barrier open
OP
(flashing)
Barrier opening
XX
(countdown)
Barrier on standby
STOP
Operator unlocked
PA
(static)
Pause (operation not complete)
rS
(static)
Barrier searching for close position
D3 and D4:
C5
Closing safety device activated
E1
Encoder motor halted
F1
Thrust limit exceeded
bA
Battery working
Ftço
Photocells defective (pre-testing)
Indications during programming
D1 (Menus): Shows the selected menu. The following
menus are available:
C
Menu Prior Conditions
P
Menu programming
F
Menu Main Functions
A
Menu Advanced Functions
ç
Operation Counter
D2 (Parameters):
Shows each parameter of the selected D1 menu.
D3 - D4 (Parameter Values):
Shows the value or option of the selected D2
parameter.
English
59
NET barriers