Operation Mode Selection (Sw2); Starting Up - Erreka KUBAR Mode D'emploi

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

10

OPERATION MODE SELECTION (SW2)

DIP1: automatic or step-by-step closing mode
• DIP1=ON: automatic mode (the barrier closes
automatically after the standby time has passed,
which is adjusted using T.E.).
• DIP1=OFF: step-by-step mode (the barrier only
closes when receiving the key command).
DIP2 (AEP1-008 / AEP1-08M): step-by-step or
collective opening
• DIP2=ON: step-by-step opening (the barrier can
be stopped by operating the command device
during opening. The barrier closes if pressed again).
• DIP2=OFF: collective opening (the panel does not
obey the command device during opening).
11

STARTING UP

Closing thrust check
Installation must respect the values indicated
in Standard EN 12453:2000. All measurements
must be made in line with the method
described in Standard EN 12445:2000.
• F
< 400N in all cases
d
DIP2 (AEP1-009 / AEP1-09M): reverse impulse
• DIP2=ON: reverse impulse enabled (when
opening begins, there is a small backward
movement of the leaf in order to help release
the electrolock).
• DIP2=OFF: reverse impulse disabled.
DIP3: automatic mode optional (only if DIP1=ON)
• DIP3=ON: during standby, the barrier obeys the
command device (this can be closed before standby
time finishes).
• DIP3=OFF: the barrier cannot be closed until
standby time finishes.
User instruction
1 Instruct the user with regards to the use and
maintenance of the installation and provide him/her
with the user guide.
2 Signpost the barrier, showing that it opens
automatically and indicating how to operate it
manually.
Where
appropriate,
operation is using the remote control.
INSTALLATION
indicate
that
41
KUBAR Barriers

Publicité

Table des Matières
loading

Table des Matières