DESCRIPTION OF THE PRODUCT
2
FEATURES
NET barriers, with built-in control board, are equipped
with a slowdown system which reduces speed at the
end of the opening and closing operations, in order to
increase safety and operation smoothness.
General features
• Control of the open/close by way of encoder
• Adjustable speed
• Adjustable maximum thrust
• Adjustable standby time in automatic cycle
• Opening and closing safety device cable connectors
(strips or photocells)
Notable features
Self-testing of photocells (programmable)
The control panel tests the photocells before starting
each closing operation. Should a failure be detected,
the operation is not carried out.
Garage light (programmable)
The garage light time can be programmed between 3
and 240 seconds. Time begins to count when the
operation starts.
Flashing light
The light remains on during the opening and closing
operations.
The light goes off when the operation finishes. The light
goes off whenever operation is interrupted at an
intermediate point.
Operation pre-warning function
(programmable)
This function delays the start of operation by three
seconds, during which time the flashing light comes on
to warn us that operation is about to begin.
Traffic light
A traffic light can be connected if the AEPS1-001 card
is installed. Using colour lights, these will indicate the
suitability or otherwise of crossing the barrier.
• Off: barrier closed
• Green light: barrier open, free passage
• Red light: barrier in movement, passage forbidden
• Flashing green light: open barrier about to close (in
automatic mode)
48
Installation Manual
NET barriers allow us to fulfil the requirements of
standard EN 12453 without the need for peripheral
elements.
• Connector for plug-in receiver
• Connector for traffic light card (AEPS1-001)
• 24Vdc cable connector for peripheral connection
• Emergency battery input
SCA Light
A 24V SCA light can be connected.
• The light remains off when the barrier is closed.
• The SCA light remains on statically when the barrier
is open.
• During opening, the SCA light flashes every second.
• During closing, the SCA light flashes every half a
second.
Slowdown function (programmable)
Function which reduces the speed of the motor at the
end of the opening and closing operation.
24Vdc battery (bA)
It is possible to connect a battery in order for the
operator to continue working in the event of a drop in
power. The battery will be recharged when the
electricity supply is restored.
Reset (rS)
Reset is the closed barrier position search at slow speed.
The display shows rS.
The operator carries out a reset in the following cases:
• When the electricity supply is restored following
interruption, and a key command is activated
• When the operator for manual operation is
unlocked and locked again
When the barrier collides with an obstacle three
consecutive times