Troubleshooting
9
Troubleshooting
Fault description
Unit does not function
'Container reserve'
lights up in display
'Container empty' lights up in
display and red LED flashes
'Alarm' and 'Rotorspray' light up in
display and red LED flashes
'Alarm' and 'Solenoid valve' light
up in display and red LED flashes
When the cause of the problem has been removed, press 'ENTER' to
acknowledge the fault.
When the cause of the problem has been removed the applicator is ready
to work again.
417101357 Rev. 3-05.2019
Cause
Wrong mains voltage
Defective fuse
Reserve signal active
Supply container is
empty
Cable has been pulled
out or is defective
although container is
full
Rotor spray not
connected but active
in parameter mode
Rotor spray
connection cable
defective
Rotor spray defective
Connection cable to
solenoid valve
defective
Solenoid valve
defective
28
Remedy
Check the applicator adjustment
Ä Chapter 7.1.1.1 'Setting
(see
the mains voltage' on page 23)
Replace fuse
Fill container (the unit is ready for
operation even if it is not refilled
(see
linktarget [417101357 08 Wartungssarbeiten]
doesn't exist but @y.link.required='true'
Refill product (see
linktarget [417101357 08
Wartungssarbeiten] doesn't exist but
)
@y.link.required='true'
Connect or replace empty signal
cable
Connect rotor spray or make rotor
spray inactive in parameter mode
(see
linktarget [417101357 06 Betrieb] doesn't exist but
)
@y.link.required='true'
Replace connection cable
Replace rotor spray
Replace connection cable
Replace solenoid valve
)