Structure of the MULTILINE 1000

10
11
9
A
12
Fig. 1: Structure of the MULTILINE 1000
1
LC display
2
'Alarm' display (red)
Function:
Flashes, if a fault is present or the empty signal has
been activated. Further detail provided in display
3
Pressure gauge
Function:
Display of tank pressure
4
Pressure adjustment control
Function:
Setting of tank pressure
5
Acknowledgement key 'ENTER'
Function:
Used to confirm parameters set or to interrupt
application
6
Adjustment key 'down'
Function:
Used to adjust application time or set parameters
7
Adjustment key 'up'
Function:
Used to adjust application time or set parameters
8
Manual operation key
Function:
Manual mode is activated by pressing the 'MAN' key
9
Continuous/automatic operation change-over key
Function:
2
1
5
8
7
6
B
C
13
14
19
Structure of the MULTILINE 1000
4
3
D
E
F
G
15
16
17
18
19
This key is used to switch between automatic and
continuous modes. The relevant LED lights up
10
'Automatic operation' display
Function:
Device is in automatic mode
11
'Continuous operation' display (green)
Function:
Device is in continuous mode
12 Compressed air input
13 Valve control pressure
14 Tank pressure
15 Rotor spray connection
16 Start signal connection
17 Reserve signal connection
18 Empty signal alarm connection
19 Mains switch with voltage selector and fuse
Function:
ON/OFF - selection of mains voltage (230 V or 115 V)
A
Compressed air input
B
EP valve control
C
Pressure tank
D
Rotor spray control
E
Start signal input/"completed" message output Alarm
output
F
Reserve signal input
G
Empty signal input
417101357 Rev. 3-05.2019