5. Output and accessories
Output
Value - Accessories
0 1
-
+
AUX
11 ... 1
24 V 120 mA max
12 ... 1
24 V 120 mA max
U
W
V
M1
N W ...
N
C
...
J12
Description
Accessories power supply.
Power supply output for external accessories, including automa-
24 V 0,5 A
tion status lamps.
The control panel has one space for coupling board, type radio
receivers, magnetic loops etc.
SOFA1-SOFA2
The coupling board working mode is selected by DIP1.
GOPAV
WARNING: the plug-in cards must be inserted and removed with the
power supply disconnected.
Automation open lamp.
Only with the limit switch 0-11 (N.C.) connected and DIP2=OFF will
the light switch off when the automation is closed.
24 V 3 W
Automation closed lamp.
With DIP2=ON, the light switches off when the automation is open.
QIKLUX
Light kit for QIK barrier.
With DIP2=ON, the light switches off when the automation is open.
Automation closed lamp.
Only with the limit switch 0-12 (N.C.) connected and DIP2=OFF will
the light switch off when the automation is open.
24 V 3 W
Automation open lamp.
With DIP2=ON, the light switches off when the automation is closed.
QIKLUX
Light kit for QIK barrier.
With DIP2=OFF, the light switches off when the automation is open.
Motor 1 (M1).
Terminal W must be connected to the common motor phase connec-
230 V~ 5 A
tion. The condenser must be connected between the U and V phases.
120 V (E1AJ)
Flashing light.
Activated during opening and closing operations.
LAMP
230 V~ 25 W
120 V~ (E1AJ)
Courtesy light in CROSS sliding automation.
LUXK7
Comes on for 180 seconds after receiving any opening (total or
230 V~ 60 W
partial) or closing command.
120 V~ (E1AJ)
Drive unit external courtesy light. Comes on for 180 seconds after
230 V~ 100 W
receiving any opening (total or partial) or closing command.
120 V~ (E1AJ)
Membrane push-button panel (PT3). Starts the opening operation.
NOTE: to activate the closing operation, connect the connector of
the push-button panel to J12 (rotated by 180°).
Membrane push-button panel (PT3). Causes the blocking of the
movement.
Membrane push-button panel (PT3). Starts the closing operation.
NOTE: to activate the opening operation, connect the connector of
the push-button panel to J12 (rotated by 180°).
WARNING: use a double insulated cable
WARNING: use a double insulated cable
30