Manitowoc iAuCS Manuel D'installation, D'utilisation Et D'entretien page 8

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation Instructions
Communication Wire and Vinyl Tubing
The communication wire and vinyl tubing must be
installed in conduit to protect them from damage.
1. Remove the 7/8" knockout hole plug located on the
back of the ice machine.
2. Install conduit from the AuCS® unit to the ice
machine. A pulling elbow is recommended for easier
routing of the vinyl tubing and modular wire.
3. Route low voltage communication wire and vinyl
tubing together through the conduit.
4. Route modular wire through control box low voltage
heyco fitting. Do not route with line voltage wiring,
erratic operation could result. Connect modular wire
to control board.
5. Connect the communication wire to the AuCS
control board.
iAuCS® Control Board
iAuCS
Communication
Plug Connection
8
Vinyl Tubing Connection
1. Remove the water trough.
A. Depress tabs on right and left side of the water
trough.
B. Allow front of water trough to drop as you pull
forward to disengage the rear pins.
2. Locate the water inlet tube on the right hand side
(see below) of the ice machine base.
After serial number 1101246915 - Use a screwdriver
to remove membrane.
Before serial number 1101246915 - Press up on the
plug until it is out.
Plug Location
Press up on
bottom of plug
to pop out
Section 2
Water Inlet
Tubing
After Serial Number
1101246915 use
screwdriver to
remove membrane
Part Number 000009036 8/13