4. Remove the backing from the adhesive bumpers.
Attach bumpers to the mounting bracket directly
above the AuCS® control box. This eliminates
upward movement and stops the tabs from
disengaging the key slots.
Mounting
Bracket
Mounting to Ice Machine
Mounting to Wall
The AuCS® is mounted to the wall using the two key
slots in the back wall of the accessory. Screw fasteners
(not supplied) must hold the entire weight of the 
AuCS® (approximately 10 lbs. [4.5 kg]).
Key Slot Dimensions
Part Number 000009036 8/13
Gasket
Bumper
6.56 in.
(16.6 cm)

CONNECTION TO ICE MACHINE

Electrical Connections
1. Check electrical code for your area.
When local code allows, the included wire and strain
relief can be used for line voltage wiring. Remove
knockout from ice machine and install strain relief
and wire.
When conduit is required remove strain relief and ice
machine electrical knockout. Install conduit as
required by your electrical code.
!
Disconnect the electrical power supply to the ice
machine
at
the
electrical
proceeding.
Connections on ice machines vary. Refer to the
diagram for the ice machine you are working on.
2. Remove the front, top, and right side panels from the
ice machine.
3. Route line voltage wires through control box line
voltage heyco fitting. Connect line voltage wires to
incoming power supply of contactor and ground
screw.
NOTE: On QuietQube Ice Machines the power
connection is made at the incoming power supply (L1
and L2). Cut-off yellow terminal (L2) and purple terminal
(L1) on AuCS harness. Strip insulation back 1/2" and
connect.
Connect to
incoming power
supply of contactor
observing proper
polarity for 115V
Installation Instructions
Warning
disconnect
before
Low Voltage
Heyco
Fittings
Connect
ground wire
to ground
screw
Line Voltage
Heyco
Fittings
7