Télécharger Imprimer la page

tau DC16 Notice D'installation page 26

Publicité

Les langues disponibles

Les langues disponibles

INSIDE SEN-
11
SOR TEST
OUTSIDE SEN-
12
SOR TEST
Dip switch SW2
1
2
3
DOORS
4
DIRECTION
If the automatic door has a single leaf opening to the right, it is necessary to re-
verse the controls of the dip switch 4 as follows: ON: opening towards the left -
OFF: opening towards the right (standard)
5
6
BATTERY CHARGER KEY
Key:
LED steady on;
LED flashing;
GREEN LED – battery charger status
off
flashing every 2 seconds
continuous flashing
flashing every 4 seconds
steadily lit
RED LED – fault diagnostics
off
steadily lit
continuous flashing
flashing every 2 seconds
AUTOMATIC OPERATION RESETTING - REALIGNMENT
When the board is powered or if the status of the inputs is unknown, the software must realign
the automation to determine the initial position.
The direction of the realignment depends on the program selected and the command given.
ATTENTION: if there are any "motor" alarms, the automatic reset timer is inhibited.
26
Enables internal sensor test – the test is carried out on the input,
ON
PICTURE1
OFF Disables the test on the input, PICTURE1
Enables external sensor test – the test is carried out on the input,
ON
PICTURE2
OFF Disables the test on the input, PICTURE2
ON
OFF Keep the Dip switch in OFF
ON
OFF Keep the Dip switch in OFF
ON
OFF Keep the Dip switch in OFF
ON
Opening towards the right
OFF Opening towards the left
ON
OFF Keep the Dip switch in OFF
ON
OFF Keep the Dip switch in OFF
battery charger off;
initial slow charge;
under fast charge;
in backup;
battery charged;
everything OK;
FAULTY battery (cell voltage < than the minimum or .....)
short circuit
battery not connected
DC16

Publicité

loading